33
1
Cable connection to the rain sensor in the housing cover
2
Connections for the drive mechanism (tension clamp, PE/N/up/down),
suitable for solid conductors up to 1.5 mm² or conductors with fine wires
3
Opening for the cable for the drive mechanism
4
Connections for voltage supply (230 V AC, tension clamp, L1/N/PE), suitable
for massive conductors of up to 1.5 mm² or conductors with fine wires.
5
Opening for the cable for voltage supply
6 Microfuse
6.3
A
7
Programming LED. In normal operation, this LED indicates the receipt of a
valid data package by a short flashing
8
Programming key for the teaching in of the radio connection to the
operating unit
Connection of voltage supply and drive mechanism
The drive mechanism of the awning or blind is connected to the weather station.
Several drive mechanisms may be connected in parallel. In case of the parallel
connection of motors, please observe whether a group control relay is specified
by the motor manufacturer. Group control relays may be provided by Elsner
Elektronik or the motor manufacturer.
If motors are connected in parallel which are not suited for
this purpose, both motor and control system are damaged.