Data Logger DL210
Elster-Instromet GmbH
51
3.2.6 Application as high flow display device
With the function "High flow display device" the end-readings from both counters relevant
for billing and the maxima (measurement period and day maxima) formed in the DL210
are included in the
month archive
of Input 1.
The counter increments per measurement period and per day are determined separately
as the measurement period flow and day flow and are temporarily saved. The current and
last saved values can be called up via the DL210 display. At the end of each month the
counter reading and the highest of these two flow values for the input are saved in the
corresponding month archive. The month archive has a depth of 15 entries so that the
maximum measurement period and daily flow of the last 15 months can be called up on
the display.
The values of the month archive can only be cleared with the calibration lock open and can
therefore be used for billing purposes.
The calibrated counters (V1 and V2) and the adjustable counters (V1.A and V2.A) are
saved in the archive. Consequently, both counters are available for billing.
The following values are in the archive, calibrated or uncalibrated:
ABNo
Date/
time
V1
V1.A
V1M.L
max
Date/
time
Stat
V1D.L
max
Date/
time
Stat
ST.1
St.Sy Check
-
calib'd.
calib'
d.
un-
calib'd
calib'd. calib'd.
un-
calib'
d
calib'd. calib'd.
un-
calib'd
un-
calib'd
un-
calib'd
-
The meanings of the individual settings are described in Chapter 3.2.2.
The maximum consumption within the measurement period from the last month is given in
"
V1M.Lmax
" or the day maximum from the last month is given in "
V1D.Lmax
" and each is
derived from the
calibrated main counter
of Input 1. Settings of counters via the keypad
or interface are neutralised for the formation of the consumption values and therefore also
have no influence over the maxima.
Summary of Contents for DL210
Page 2: ...Data Logger DL210 2 Elster Instromet GmbH ...
Page 9: ...Data Logger DL210 Elster Instromet GmbH 9 ...
Page 10: ...Data Logger DL210 10 Elster Instromet GmbH ...
Page 11: ...Data Logger DL210 Elster Instromet GmbH 11 Part 1 Device description relevant to calibration ...
Page 101: ...Data Logger DL210 Elster Instromet GmbH 101 Part 2 Description of the Initial operation ...
Page 118: ...Data Logger DL210 118 Elster Instromet GmbH Appendix ...