3.7 User list
Name Address Designation / value
Cal.
Access Default DC
V1.A
1:203
Adjustable counter I1
No
S
0
3
V1
1:200
Main Counter I1
Yes
PL
0
3
V1M.L
max
3:0161 Max. meas. period consumption in last month
Yes
P
0
1
Date 3:0165_1 Date of the maximum of the meas. period counter
I1 in the last month
Yes
P
-
1
Time 3:0165_2 Time of the maximum of the meas. period counter
I1 in the last month
Yes
P
-
1
V1D.L
max
4:0161 Max. day counter I1, last month
Yes
P
0
1
Date 4:0165_1 Date of the maximum of the day counter I1 in the
last month
Yes
P
-
1
Time 4:0165_2 Time of the maximum of the day counter I1 in the
last month
Yes
P
-
1
S.Reg
1:101
Status register
No
-
0
1
StM
2:77C_1 Modem status
-
-
Logged
out
2
Bat.R
2:404
Remaining battery service life
-
-
-
2
Time
1:400
Time and with to date
Yes
S
-
2
Menu
1:1A1 Selection for display menu
-
S
1
7
DC
= Data class (for description see Chap. 2.5.1, page 25.)
P/PL/S/C
= The displayed value is subject to: "
P
": Calibration lock "
PL
": PTB logbook "
S
":
Supplier's lock "
C
": Customer's lock "-": Value cannot be changed..
With exception of the last value, this list is application-specific, i.e. the user can himself set
which values in this list are displayed. Ex-works, these are the above-mentioned values
(default) which are also all displayed in another list and described in the corresponding
chapters.
The setting of the values to be displayed occurs by entering the addresses of the values to
be displayed with the parameterisation software "WinPADS" - "Configuration", "Display"
under the addresses "1:1C2" to "12:1C2".
With
Menu
the complete display structure of the DL210 can be switched between
"complete" and "simple".
Menu
=
Meaning
1
Complete display structure
2
Only "
User
" column
Summary of Contents for DL210
Page 2: ...Data Logger DL210 2 Elster Instromet GmbH ...
Page 9: ...Data Logger DL210 Elster Instromet GmbH 9 ...
Page 10: ...Data Logger DL210 10 Elster Instromet GmbH ...
Page 11: ...Data Logger DL210 Elster Instromet GmbH 11 Part 1 Device description relevant to calibration ...
Page 101: ...Data Logger DL210 Elster Instromet GmbH 101 Part 2 Description of the Initial operation ...
Page 118: ...Data Logger DL210 118 Elster Instromet GmbH Appendix ...