42
Assembly
, Connection and Putting into Operation
"+" of the encoder to the "DE1 +" terminal and "-" to the "DE1 -"
terminal respectively.
2. Adjust the measurement parameters, e.g. the encoder type, as
described in chapter 5.3.1.3.
5.2.2 Sealing the input terminals
After connecting to the meter as per chapter 5.2.1 the respective
DE1 to DE4 input terminal must be sealed for official calibration
measurements. For this purpose, terminal covers are provided in the
bag of accessories. If required, these should be screwed over the
connected terminals and an adhesive seal should then be bonded to
the fastening screw (see chapter 5.3.2).
5.2.3 Connecting the power supply
5.2.3.1 Power supply for the DL230 with integrated power
supply unit
DANGER!
Danger to life from electrical current!
Touching live parts poses an imminent danger to life.
Therefore:
– Works on the electrical components of the device,
i.e. the connection of the power supply unit, should
solely be carried out by qualified electricians.
– When performing all works to the electrical system,
switch off the power, secure it against an
accidental restart and check to ensure that the
voltage has been cut.
– Keep live parts away from moisture. This could
lead to a short-circuit.
The power supply unit to connect the 230 V~ power supply, is
in-built into the base of the DL230.
Summary of Contents for DL230
Page 1: ...Operating manual Data Logger DL230 ...
Page 8: ......
Page 105: ...Appendix 105 English manual 73 022 387 ...
Page 106: ...106 Appendix 9 2 EC Declaration of Conformity ...
Page 107: ...Appendix 107 9 3 ATEX Type Examination Certificate 9 3 1 Associated apparatus for Zone 0 1 ...
Page 108: ...108 Appendix ...
Page 109: ...Appendix 109 ...
Page 110: ...110 Appendix ...