Assembly
, Connection and Putting into Operation
43
III. 9
1. Switch off the supply voltage and secure
it against an accidental restart!
2. Connect the 230V~ supply voltage to the
terminal block (
1 ) of the power supply.
Terminal "PE" is the connection for the
protective conductor (protective
earthing).
The wire cross-section for the connection to the inte-
grated power supply unit is 0.2 … 1.5 mm
2
.
DANGER!
Danger to life from electrical current!
Connect the protective earthing of the mains power
supply to the J2 screw terminal, connection "E"!
5.2.4 Connect outputs of the DL230
DANGER!
The connection of non-intrinsically-safe or non-
associated apparatus presents a risk of explosion!
The operation of the DL230 as associated apparatus for
zone 0 or 1 and the connection of non-intrinsically-safe
equipment which exceeds those conditions and limit
values specified in the declaration of conformity, pre-
sents a risk of explosion.
Therefore:
– When the DL230 is used as associated apparatus
only devices with intrinsically-safe circuits and
electrical data that corresponds to those
requirements stipulated in the declaration of
conformity for the DL230 (see Appendix), should be
connected.