72
Operation
Display Description
Unit Access
Ad-
dress
V1MPL
∆
Consumption during the last
measurement period at
input 1
m
3
-
1:161
V2MPL
∆
Consumption during the last
measurement period at
input 2
m
3
-
5:161
V3MPL
∆
Consumption during the last
measurement period at
input 3
m
3
-
9:161
V4MPL
∆
Consumption during the last
measurement period at
input 4
m
3
-
13:161
6.4.3.1 VxMPL
– Maximum measurement period counter of the
respective input in the previous month
The displayed value is the metering period maximum of the counter
input determined up to this point in the current month. The maximum
time stamp is displayed in the following line after moving the cursor
to the value "VxMPL
".
The maximum values from the past 15 months can be requested in
the monthly archive 1 (see chapter 6.4.4 "Admin" Register
(Administrator).
6.4.3.2 VxDGL
– Maximum daily counter of the respective in-
put in the previous month
The value is the daily maximum of the counter input determined up
to this point in the current month regardless of the daily limit. The
maximum time stamp is displayed in the following line after moving
the cursor to the value "VxTGL
".
The maximum values from the past 15 months can be requested in
the monthly archive 1 (see chapter 6.4.4 "Admin" Register
(Administrator).
Summary of Contents for DL230
Page 1: ...Operating manual Data Logger DL230 ...
Page 8: ......
Page 105: ...Appendix 105 English manual 73 022 387 ...
Page 106: ...106 Appendix 9 2 EC Declaration of Conformity ...
Page 107: ...Appendix 107 9 3 ATEX Type Examination Certificate 9 3 1 Associated apparatus for Zone 0 1 ...
Page 108: ...108 Appendix ...
Page 109: ...Appendix 109 ...
Page 110: ...110 Appendix ...