82
Operation
lock is open. Otherwise the value can only be changed when the
calibration lock is open. Sensible and typical values include 5, 10,
15, 20, 30 or 60 minutes.
For monitoring invoicing data on the display, the device is equipped
with the following functions:
All invoicing-relevant data is displayed under:
Admin
Input x
Measurement period Ix
Additional display of the progress of the counter (consumption
values) in the measurement period archive
Search function for checking archive entries (see Chapter 6.6.1)
Display of the set measurement period
MP Ix
and the remaining
duration of the current measurement period under:
Admin
Input x
MP.Ix or MP.Re
Labelling of uncalibrated values using an asterisk in front of the
short description