STANDARD CONFORMITY
2014/35/EU Low Voltage Directive (LVD)
2014/30/EU Electromagnetic Compatibility (EMC),
in conformity with the following standards:
Electrical Safety: EN60335-1(2012)+A11+A13; EN 60335-2-80(2003)+A1+A2.
Electromagnetic Compatibility: EN 55014-1(2017); EN 55014-2(2015); EN 61000-3-2(2014); EN 61000-3-3(2013).
GUARANTEE
The product is offered with a five year warranty.
First year of warranty covers parts and labour. Following this period the warranty covers
replacement parts only based on maintenance having being carried out in accordance with our literature and terms and conditions of sale.
Proof of Purchase, periodic inspection and maintenance will be required in the event of any warranty claim.
a)
Mark
-
Elta Fans
b)
Model
-
SANO IPIV Loft
c)
SEC class
-
C
c1)
SEC warm climates
kWh/m
2
.a
-10.7
c2)
SEC average climates
kWh/m
2
.a
-25.1
c3)
SEC cold climates
kWh/m
2
.a
-50.2
Energy label
-
No
d)
Unit typology
-
Residential - unidirectional
e)
Type of drive
-
Multi-speed drive
f)
Type of Heat Recovery System
-
Absent
g)
Thermal efficiency of heat recovery
%
N/A
h)
Maximum flow rate
m
3
/h
288
i)
Electric power input at maximum flow rate
W
29
j)
Sound power level (L
WA
)
dBA
43
k)
Reference flow rate
m
3
/h
202
l)
Reference pressure difference
Pa
10
m)
Specific power input (SPI)
W/m
3
/h
0.054
n1)
Control factor
-
0.65
n2)
Control typology
-
Local demand control
o1)
Maximum internal leakage rate
%
N / A
o2)
Maximum external leakage rate
%
N / A
p1)
Internal mixing rate
%
N / A
p2)
External mixing rate
%
N / A
q)
Visual filter warning
-
N / A
r)
Instructions to install regulated grilles
-
Check the instruction booklet
s)
Internet address for pre / disassembly instructions
-
www.eltafans.com
t)
Airflow sensitivity to pressure variations
%
10
u)
Indoor / outdoor air tightness
m
3
/h
101
v1)
AEC - Annual electricity consumption - warm climates
kWh
0.4
v2)
AEC - Annual electricity consumption - average climates
kWh
0.4
v3)
AEC - Annual electricity consumption - cold climates
kWh
0.4
w1)
AHS - Annual heating saved - warm climates
kWh
11.9
w2) AHS - Annual heating saved - average climates
kWh
26.2
w3) AHS - Annual heating saved - cold climates
kWh
51.3
ErP DIRECTIVE - REGULATIONS 1253 / 2014 - 1254 / 2014