Table 14 – Parameters of events in the active alarms log
Token
Description
severity
Describes event severity. Has four states:
(info, minor, major, critical)
in
Specifies whether an SNMP trap should be sent when an event is added to the log. Has two states:
(true/false)
out
Specifies whether an SNMP trap should be sent when an event is deleted from the log (normalization). Has
two states:
(true/false)
4.4.4.1 Active alarms log configuration
Step 1.
To configure the active alarm log, go to
configure view
and then to
alarm view
.
LTP-16N# configure terminal
LTP-16N(configure)# alarm
LTP-16N(config)(alarm)#
Step 2.
For example, configure the alarm system-fan. To do this use the
system-fan
command. The
other alarms are configured similarly.
LTP-16N(config)(alarm)# system-fan min-rpm 5000
LTP-16N(config)(alarm)# system-fan severity critical
LTP-16N(config)(alarm)# system-fan in true
Step 3.
Apply the changes by using the
do commit
command.
LTP-16N(config)(alarm)# do commit
4.5 VLAN Configuration
4.5.1 Introduction
This section describes VLAN configuration.
VLAN ( Virtual Local Area Network) is a group of devices, which communicate on the channel level and are
combined into a virtual network, connected to one or more network devices (GPON terminals or switches).
VLAN is a very important tool for creating a flexible and configurable logical network topology over the
physical topology of a GPON network.