Chapter 7.
Safety Precautions and Installation Procedure
Introduction
This chapter describes installation of the terminal into a rack and connection to power supply.
7.1
Safety Requirements
General
Any operations with the terminal should comply with the Safety Rules for Operation of Customers'
Electrical Installations.
Only personnel authorised in accordance with the safety requirements should carry
out operations with the terminal.
1.
Before operating the terminal, all engineers should undergo special training.
2.
The terminal should be connected only to properly functioning equipment.
3.
The terminal is dedicated to 24/7 operation in environment complying with the following requirements:
-
ambient temperature from +5 to +40°C;
-
relative humidity up to 80% at +25°C;
-
atmosphere pressure from 6.0×10
4
to 10.7×10
4
Pa (from 450 to 800 mm Hg).
4.
The terminal should not be exposed to mechanical shock, vibration, smoke, dust, water, and
chemicals.
5.
In order to avoid components overheating, which may result in terminal malfunction, do not block air
vents or place objects on the terminal.
Electrical Safety Rules
1.
Prior to connecting the terminal to a power source, ensure that the terminal case is grounded with an
earth bonding point. The earthing wire should be securely connected to the earth bonding point. The
resistance between the earth bonding point and the earthing busbar should be less than 0.1 Ohm.
Summary of Contents for LTP-4X
Page 11: ...11 Part I General ...
Page 29: ...29 Part II Getting Started with the Terminal ...
Page 37: ...37 Part III Configuring the Terminal ...
Page 98: ...98 Part IV ONT Configuration ...
Page 174: ...174 Part V Terminal Monitoring ...
Page 189: ...189 Part VI Terminal Maintenance ...
Page 191: ...191 Step 2 Remove the module from the slot Fig 43 4 Removing SFP Transceivers ...