20
BA-en-3021-1912_R23ATR
4. Operation
4.1 Setting the operating voltage
The operating voltage on the high voltage generator is set at between
15 and 25 kV depending on the distance "a" of the emission tips from the
substrate.
The correct operating voltage is set as soon as the desired effect is
achieved by using the charging bar.
Caution!
Uncontrolled sparking on the charging bar must be avoided.
Reduce the high voltage or increase the distance from the substrate.