18
BA-en-3021-1912_R23ATR
3.5 Connecting the high voltage cable of the charging bar to the
high voltage generator POWER CHARGER PCSC
Warning!
Electric shock hazard!
Work may be carried out only if:
• the supply voltage to the generator has been disconnected,
• the machine is at a standstill because the bars pick up charges if the
material web is running.
Method:
Connect the bars via the prefabricated high voltage cable. Push the high
voltage cables up to the stop into the socket connection. Finally, the crew
connection is tightened.
9 / 9.1 High voltage outputs
10 High voltage cable
Note:
The screw connection must be fastened with a torque of 3 Nm.
Caution!
The high voltage cable must be pushed up to the stop (150 mm) into the
cable inlet! The connecting area of the high voltage cable must be kept
clean!
Fig. 14:
Connecting the
high voltage cable
Z-
11
60
35
ay_
4