Universal Network Terminal TAU-32M.IP 75
–
Syslog Port
– port for Syslog server incoming messages (514 by default);
Record type (APPLICATION):
–
Error
–send application failure messages to Syslog server;
–
Warning
–send application warning messages to Syslog server;
–
Info
–send application Info messages to Syslog server;
–
Debug
–send application debug messages to Syslog server;
–
Alarm
– send alarm event messages to Syslog server;
SIP:
–
SIP Log Level–
SIP protocol log level;
H.323:
–
H.323 Log Level–
H.323 protocol log level;
VAPI:
–
Enabled
– when checked, VAPI library logging is enabled, otherwise it is disabled;
–
Lib Level–
VAPI library log level;
–
App Level
–VAPI log level from the application side.
Use
Start and Stop
buttons to start and stop the output of logging information to the system log.
Use
Show
and
Clear
buttons available in syslog file saving mode to view the log via web interface and clear the
log on the device.
To discard all changes made to configuration, click the
Undo All Changes button.
To apply changes, click the
Submit Changes
button.
5.1.1.8
The 'MAC filter' submenu
In the 'MAC filter' submenu, you may configure lists of permitted and denied MAC addresses from which the
device is available.
–
Filter mode
– three operation modes are available: disabled, 'black list' or 'white list';
To add MAC address to the table, enter the required address in the
'MAC address'
column in