____________________________________________________________________________________
____________________________________________________________________________________
TAU-4M.IP Subscriber gateway
117
5
DEVICE AUTOMATIC UPDATE ALGORITHM BASED ON DHCP
Automatic device update procedure algorithm is determined by the
'Parameters priority from'
parameter value.
If
'Static settings'
value is selected, then the full path (including the access protocol and server address) to
the configuration files and firmware is determined from the
'Configuration file'
and
'Firmware file'
parameters. The full path is specified in the URL format (HTTP and TFTP are supported):
<protocol>://<server address>/<path to file>, where
<protocol> – protocol that used for downloading the corresponding file from server (supports HTTP
and TFTP);
<server address> – address of the server from wnich the file should be downloaded (domain name or
IPv4);
<path to file> – path to file on server.
The following macros are allowed in the URL (reserved words, instead of which the device substitutes
certain values):
$MA
– MAC address – instead of this macro, the device inserts its own MAC address in the file URL;
$SN
– Serial number – instead of this macro, the device inserts its own serial number in the file URL;
$PN
– Product name – instead of this macro, the device inserts its product name (e.g. TAU-4M.IP) in
the file URL;
$SWVER
– Software version – instead of this macro, the device inserts its firmware version number in
the file URL;
$HWVER
– Hardware version – instead of this macro, the device inserts its hardware version number
in the file URL.
The MAC address, serial number and model name can be found on the monitoring page in the 'Device'