DHCP-based Autoprovisioning:
Provisioning Mode
– select a mode for automatic device update. The followings are available:
Disabled
– automatic update of configuration and firmware is disabled;
Configuration and Firmware
– periodical configuration and firmware update is permitted;
Configuration only
– only periodical update of configuration is permitted;
Firmware only
– only periodical update of firmware is permitted.
Parameters Priority from
– the parameter defines names and locations of configuration and firmware files:
Static settings
– paths to configuration and firmware files are defined by the
«Configuration file»
and
«Firmware file»
settings correspondingly; more detailed information on the algorithm see in section
An algorithm of automatic update based on DHCP
DHCP options
– paths to configuration and firmware files are defined by the DHCP Option 43, 66, and
67 (to do this, you should select DHCP for the Internet service); more detailed information on the
algorithm see in section
An algorithm of automatic update based on DHCP
;
Configuration File
– full path to configuration file – set in URL format (there is an opportunity to load
configuration files via TFTP and HTTP):
tftp://<server address>/<full path to cfg file>
http://<server address>/<full path to cfg file>
where < server address > – HTTP- or TFTP server address (domain name or IPv4),
< full path to cfg file > – full path to configuration file on the server;
Configuration Upgrade interval, s
- the time interval in seconds, after which the device configuration is
periodically updated. If 0 is set, update of the device will be implemented once, right after reloading of the
device;
Firmware File
– full path to firmware file – set in URL format (there is an opportunity to load configuration
files via TFTP and HTTP):
tftp://<server address>/<full path to firmware file>
http://<server address>/<full path to firmware file>
where< server address > – HTTP or TFTP server address (domain name or IPv4),
< full path to firmware file > – full path to configuration file on the server.
Firmware Upgrade Interval, s
– a time interval. The firmware update is implemented according to this period.
If 0 is set, update of the device will be implemented once, right after reloading of the device.
More detailed information on the algorithm see in section
An algorithm of automatic update based on DHCP
Autoprovisioning via TR-069:
Common:
Enable TR-069 Client
– when checked, the operation of embedded TR-069 client is enabled, otherwise it is
prohibitted;
ACS Server Address
– autoconfiguration server address. The address should be enterred in the following
formats http://<address>:<port> or https://<address>:<port> (<address> – IP address or domain name of
ACS server, <port> – ACS server port, the default port is 9595). The second format is to use the secure
protocol – HTTPS for exchanging data with ACS server;
Enable Periodic Inform
– when checked, embedded TR-069 client implements periodic poll of ACS server
with interval equal to
«Periodic Inform Interval»
value in seconds. The poll aim is to detect device
configuration changes.
ACS Connection Request:
User Name, Password
– user name and password for client to access ACS server.
Client Connection Request:
User Name, Password