WOP-12ac-LR. Quick guide for FBWA configuration via web interface
7
•
•
•
•
•
•
•
•
Click the
«Switch»
button if you want to switch to an Alternative firmware image set in the
«Secondary
Image»
field;
Upload Method
– check the «HTTP» box;
New
Firmware
Image
– click the
«Select file»
button and select relevant firmware version, click
«Open»
;
Click
«Upgrade».
The update process will take several minutes (its current status will be indicated on the
page), after which the access point will automatically reboot.
2.5 Network settings:
You may check the current firmware version in the
«Basic
Settings»
menu (Firmware Version).
For remote management of WOP-12ac-LR, you should set network parameters of the device according to the
settings of the network that you intend to use.In the
«Manage»
menu, open
«Ethernet
Settings»
tab and perform
the following:
Management VLAN ID
– set the number of VLAN that you are going to use for access point management.
VLAN1 is used in the given example;
Connection
Type
– selection of the method for setting the IP address on the control interface, through
which the device's WAN interface will be connected to the provider's services network:
DHCP – operation mode, when IP address, subnet mask, DNS server address, gateway are set by
default and other parameters required for operation are obtained from DHCP server automatically;
Static IP – operation mode, when IP-address and all necessary parameters for WAN-interface are
assigned as static.
In our case, a static IP address is used on the control interface. To assign an IP address to access points
manually, select
«Static
IP»
. Specify the IP address of WOP-12ac-LR (in the example, it is 192.168.1.10) in the
Do not switch off or reboot the device during the firmware update.