maintain the DMX circuit even when one of the units’ power is
disconnected.
4)
Each unit needs to have an address setup to receive the data sent
from the controller. The address number is between 1-512
5)
3 pin wiring configuration:
3 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive
signal (+)
5. Trouble shooting
Following are a few common problems that may occur during
operation and some suggestions for easy troubleshooting:
A. The unit does not work, no light and the fan does not work
1.
Check the connection of power and the main fuse.
B. Not responding to DMX controller
1.
DMX LED should be on. If not, check DMX cables
to see if linked correctly.
2.
If the DMX LED is on and no response to the controller check the
address settings and DMX polarity.
3.
Try another DMX controller.
C. No response to the sound
1.
Make sure the unit is not receiving a DMX signal.
2.
Check the microphone to see if it is O.K. by tapping it.
The microphone is located on the base of the unit.
3.
Check that the unit is not set into “BLACKOUT” mode.
6. Fixture Cleaning
The cleaning of the external optical lenses must be carried out
periodically to optimize light output. Cleaning frequency depends on
the environment in which the fixture operates: damp, smoky or
particularly dirty surrounding can cause a greater accumulation of dirt
on the unit’s optics.
Clean with soft cloth using normal glass cleaning fluid
or mild soapy water.
Always dry the parts carefully.
Clean the external optics at least every 20 days.
----------------------www.prolight.co.uk----------------------------------