background image

1. Safety Instructions 

  

WARNING 

Please keep this User Guide for future consultation. If you sell the unit to another 

user be sure that they also receive this.

 

Unpack and check carefully that there is no transportation damage before using 

the unit.

 

Ÿ

  Before  operating,  ensure  that  the  voltage  and  frequency  of  the  power  supply 

match the power requirements of the unit.  

Ÿ

  It’s  important  to  ground  the  yellow/green  conductor  to  earth  in  order  to  avoid 

electric shock. 

Ÿ

  The unit is for indoor use only. Use only in a dry location. 

Ÿ

  The unit must be installed in a location with adequate ventilation, at least 50cm 

from adjacent surfaces. Be sure that no ventilation slots are blocked.  

Ÿ

  Disconnect the mains power before replacement or servicing.  

Ÿ

  Make sure there are no flammable materials close to the unit while operating as 

they may cause a fire hazard.  

Ÿ

  Always use a safety cable when installing this unit.   

Ÿ

  The  maximum  ambient  temperature  is:  40°.  Don’t  operate  it  where  the 

temperature is higher than this. 

Ÿ

  In  the  event  of  a  serious  operating  problem  stop  using  the  unit  immediately. 

Never try to repair the unit by yourself. Repairs carried out by unskilled people 
can  lead  to  damage  or  malfunction.  Please  contact  the  nearest  authorized 
technical assistance center. Always use the same type spare parts. 

Ÿ

  Do not touch any power cables during operation as the high voltage may cause 

an electric shock. 

Warning

 

Ÿ

  To prevent or reduce the risk of electrical shock or fire, do not expose the unit to 

rain or moisture. 

Ÿ

  Do not open the unit within five minutes after switching off. 

Ÿ

  The housing and lenses must be replaced if they are visibly damaged. 

Ÿ

  This lighting fixture is for professional use only - it is not designed for or suitable 

for  household  use.  The  product  must  be  installed  by  a  qualified  technician  in 
accordance  with  local  territory  regulations.  The  safety  of  the  installation  is  the 
responsibility of the installer. The fixture presents risks of severe injury or death 
due to fire hazards, electric shock and falls. 

Ÿ

  Warning!  Risk  Group  2  LED  product  according  to  EN  62471.  Do  not  view  the 

light output with optical instruments or any unit that may concentrate the beam. 

Ÿ

  WARRANTY: Two years from date of purchase. 

 

Installation

 

The unit should be mounted via its screw holes onto the bracket. Always ensure 

that the unit is firmly fixed to avoid vibration and slipping while operating. Make 

sure that the structure to which you are attaching the unit to is secure and is able 

to support a weight of 10 times of the unit’s weight. Always use a safety cable that 

can hold 12 times of the weight of the unit when installing the fixture.  

The equipment must be installed by professionals and it must be installed in a 
place where is out of the reach of people and no one can pass by or under it 

2. Features & Specifications  

 Extremely small, fast and powerful LED moving beam.  

 DMX Channels: 9/12/14/16/28  

 Pan/Tilt: 630/200, speed adjustable  

 Smooth electronic dimming: 0-100%  

 Electronic strobe with pulse and random effects  

 Optional easy controller CA-8 for instant lighting shows at your fingertips  

 High efficiency, low power consumption  

 Super compact, low weight 

l

  12pcs of 10

W RGBW 

quad colo

u

LED

l

 

Voltage: 100V~240V, 

50/60Hz

 

l

 

Fuse: T 6.3A

 

l

 

Power consumption: 150W

 

l

 

Dimension:

 

304 x 267 x 167 mm

 

l

 

Weight:

 

5.8 kg

 

l

 

Power sockets

:

 

IEC

 

IN/OUT

 

l

 

XLR sockets

3

-

pin XLR IN/OUT

 

 
3. How To Set The Unit  
 
3.1 Control panel  

 

Please read the instructions carefully as they include 
important information about installation, usage and 
maintenance. 

Summary of Contents for ELUM031

Page 1: ...eLumen8 KUDOS CM 120 MKII Order code ELUM031 User Manual Contents 1 Safety Instructions 2 Features Specifications 3 How To Set The Unit 4 How To Control The Unit 5 Troubleshooting 6 Fixture Cleaning ...

Page 2: ...or professional use only it is not designed for or suitable for household use The product must be installed by a qualified technician in accordance with local territory regulations The safety of the installation is the responsibility of the installer The fixture presents risks of severe injury or death due to fire hazards electric shock and falls Warning Risk Group 2 LED product according to EN 62...

Page 3: ...the display will blink Use the DOWN and UP buttons to change the mode Once the required mode has been selected press the ENTER button to confirm The main functions are as below Menu DMX Address setting 001 512 Channel mode 9CH 12CH 14CH 16CH 28CH Show mode Show 1 Show 2 Show 3 Show 4 Dimmer curve Mode 1 Mode 2 Mode 3 Mode 4 Slave mode Slave1 Slave2 Blackout Yes No Sound ON OFF Sound Sensitivity 0 ...

Page 4: ...ER button to confirm Black Out Select Blackout Mode press the ENTER button and the current mode will blink on the display Use the DOWN and UP buttons to select Yes yes blackout or No no blackout mode Once the mode has been selected press the ENTER button to confirm Sound State Select Sound State press the ENTER button and the current mode will blink on the display Use the DOWN and UP buttons to se...

Page 5: ...the ENTER button and all channels of the unit will return to their standard position 3 3 Home Position Adjust Hold the Enter button for at least 3 seconds to enter offset mode Use the DOWN and UP buttons to choose Pan Offset or Tilt Offset and then press the ENTER button and the display will blink Use the DOWN and UP buttons to adjust the home position of the Pan or Tilt Once the position has been...

Page 6: ...n to confirm Please refer to the below diagram to address your DMX512 channel for the first 4 units Channel mode Unit 1 Address Unit 2 Address Unit 3 Address Unit 4 Address 9channel 1 10 19 28 12channels 1 13 25 37 14channels 1 15 29 43 16channels 1 9 17 25 28channels 1 29 57 85 4 3 DMX 512 Configuration 9 channels mode Channel Value Function 1 000 255 Pan 2 000 255 Tilt 3 248 255 Open 240 247 Ran...

Page 7: ...lackout while Pan tilt 100 104 No function 105 109 Disable blackout while pan tilt 110 114 Dimmer speed slow to fast 115 119 No function 120 124 DIMMER 0 100 125 249 Illuminate display 250 255 Stand alone 8 Colour wheel effect 000 009 Open RGB Colour mixing 010 014 LEE790 Moroccan Pink 015 019 LEE157 Pink 020 024 LEE332 Special rose pink 025 029 LEE328 Follies pink 030 034 LEE345 Fuchsia Pink 035 ...

Page 8: ...96 215 Macro 10 176 195 Macro 9 156 175 Macro 8 136 155 Macro 7 116 135 Macro 6 096 115 Macro 5 076 095 Macro 4 056 075 Macro 3 036 055 Macro 2 016 035 Macro 1 000 015 No effect 7 000 255 Pan tilt macro speed 8 250 255 Stand By 210 249 NO Function 200 209 Reset All 090 199 NO Function 080 089 Disable Blackout while Pan Tilt Move 070 079 Enable Blackout while Pan Tilt Move 000 069 NO Function 250 2...

Page 9: ...er 10 248 255 Open 240 247 Random Strobe 232 239 Open 190 231 Slow close Fast Open 182 189 Open 140 181 Slow Open Fast close 132 139 Open 16 131 Strobe slow fast 8 15 Open 000 007 Blackout 11 000 255 Red 12 000 255 Green 13 000 255 Blue 14 000 255 White 15 000 007 Normal 008 127 Colour Macro 1 32 128 135 Colour Chase 136 143 Fade In Out 144 191 Quadrant Macro Chase 192 219 2 Colour Cross Fades 220...

Page 10: ...ite2 19 000 255 Red3 20 000 255 Green3 21 000 255 Blue3 22 000 255 White3 23 000 255 Red4 24 000 255 Green4 25 000 255 Blue4 26 000 255 White4 27 000 007 Normal 008 127 Colour Macro 1 32 128 135 Colour Chase 136 143 Fade In Out 144 191 Quadrant Macro Chase 192 219 2 Colour Cross Fade 220 255 3 Colour Cross Fade 28 000 255 Fade Speed 4 4 DMX 512 Connection 1 In the last unit the DMX cable has to be...

Page 11: ...2 If the DMX LED is on and no response to the controller check the address settings and DMX polarity 3 Try another DMX controller C No response to the sound 1 Make sure the unit is not receiving a DMX signal 2 Check the microphone to see if it is O K by tapping it The microphone is located on the base of the unit 3 Check that the unit is not set into BLACKOUT mode 6 Fixture Cleaning The cleaning o...

Reviews: