background image

Notice:  

• Be sure to follow figures 2 & 3 when making your own cables. Do not connect the cable’s shield conductor 

to the ground lug or allow the shield conductor to come in contact with the XLR’s outer casing. Grounding the 

shield could cause a short circuit and erratic behaviour.

Special Note: Line termination:

      • When longer runs of cable are used, you may need to use a terminator on the last unit to 

        avoid erratic behaviour.

Using a cable terminator (part number CABL90) will decrease the possibilities of erratic behaviour. 

5-Pin XLR DMX Connectors:

     • Some manufactures use 5-pin XLR connectors for data transmission in place of 3-pin. 5-Pin 

       XLR fixtures may be implemented in a 3-pin XLR DMX line. When inserting standard 5-pin 

       XLR connectors in to a 3-pin line a cable adaptor must be used. The Chart below details the 

       correct cable conversion.

Termination reduces signal transmission problems 
and interferance. it is always advisable to connect a 
DMX terminal, (resistance 120 Ohm 1/4 W) between 
pin 2 (DMX-) and pin 3 (DMX+) of the last fixture.

6

Summary of Contents for ELUM042

Page 1: ...50W 100W LED Zoom User Manual Code ELUM042 50W 5600K Code ELUM042A 100W 5600K Code ELUM042D 100W 3200K ...

Page 2: ...1 ...

Page 3: ...2 ...

Page 4: ...onsumption 50W version 77W Power consumption 100W version 126W Dimensions 350 x 165 x 255mm Weight 50W version 4 6Kgs Weight 100W version 5Kgs Operating modes 1 Dimming 0 100 2 DMX 3 Master slave 4 Channel select 5 Dimming curves Overview 50W Back Note To use the focus knob on the rear of the 100W fixtures simply turn the knob counter clock wise to zoom in s and turn it clockwise to zoom out L 100...

Page 5: ...en the 4 dimming curves from 01 08 1 4 are for halogen response type 01 Linear 02 Square 03 Inverse square 04 S curve 5 8 are for LED response type 05 Linear 06 Square 07 Inverse square 08 S curve When you are happy with your setting press the ENTER button to confirm it LINEAR the increase in light intensity appear to be linear as DMX value is increased SQUARE light intensity control is finer at l...

Page 6: ...s of 1 may be placed anywhere in a DMX line at the beginning at the end or anywhere in the middle When a fixture is assigned a DMX address of 1 the DMX controller knows to send DATA assigned to address 1 to that unit no matter where it is located in the DMX chain DATA Cable DMX cable requirements for DMX operation The LED Zoom can be controlled via DMX 512 protocol The DMX address is set on the ba...

Page 7: ...viour Using a cable terminator part number CABL90 will decrease the possibilities of erratic behaviour 5 Pin XLR DMX Connectors Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 Pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin XLR connectors in to a 3 pin line a cable adaptor must be used The Chart below details the correc...

Page 8: ...www elumen8 co uk ...

Reviews: