background image

1. Safety Instruction 

 

 

 

 

WARNING 

P

lease keep this User Guide for future consultation. If you sell the unit to another 

user be sure that they also receive this. 

Unpack  and  check  carefully  that  there  is  no  transportation  damage  before  using 
the unit. 

Ÿ

  Before  operating,  ensure  that  the  voltage  and  frequency  of  the  power  supply 

match the power requirements of the unit.   

Ÿ

  It’s  important  to  ground  the  yellow/green  conductor  to  earth  in  order  to  avoid 

electric shock. 

Ÿ

  The unit is for indoor use only. Use only in a dry location. 

Ÿ

  The unit must be installed in a location with adequate ventilation, at least 50cm 

from adjacent surfaces. Be sure that no ventilation slots are blocked.   

Ÿ

  Disconnect the mains power before replacement or servicing.   

Ÿ

  Make sure there are no flammable materials close to the unit while operating as 

they may cause a fire hazard.   

Ÿ

  Always use a safety cable when installing this unit. Do not carry the unit with its 

head only; always carry it using the base.     

Ÿ

  The  maximum  ambient  temperature  is:  40°.  Don’t  operate  it  where  the 

temperature is higher than this. 

Ÿ

  In  the  event  of  a  serious  operating  problem  stop  using  the  unit  immediately. 

Never try to repair the unit by yourself. Repairs carried out by unskilled people 
can lead to damage or malfunction.   
Please contact the nearest authorized technical assistance center. Always use 
the same type spare parts. 

Ÿ

  Do not touch any power cables during operation as the high voltage may cause 

an electric shock. 
 

Warning 

Ÿ

  To prevent or reduce the risk of electrical shock or fire, do not expose the unit to 

rain or moisture. 

    Do not open the unit within five minutes after switching off. 

Ÿ

  The housing and lenses must be replaced if they are visibly damaged. 

Ÿ

  This lighting fixture is for professional use only - it is not designed for or suitable 

for  household  use.  The  product  must  be  installed  by  a  qualified  technician  in 
accordance  with  local  territory  regulations.  The  safety  of  the  installation  is  the 
responsibility of the installer. The fixture presents risks of severe injury or death 
due to fire hazards, electric shock   
and falls. 

Ÿ

  Warning!  Risk  Group  2  LED  product  according  to  EN  62471.  Do  not  view  the 

light  output  with  optical  instruments  or  any  device  that  may  concentrate  the 
beam. 

Ÿ

  WARRANTY: Two years from date of purchase. 

 

Installation 

The unit should be mounted via its screw holes onto the bracket. Always ensure 

that the unit is firmly fixed to avoid vibration and slipping while operating. Make 

sure that the structure to which you are attaching the unit to is secure and is able 

to support a weight of 10 times of the unit’s weight. Always use a safety cable 

that can hold 12 times of the weight of the unit when installing the fixture.   

The equipment must be installed by professionals and it must be installed in a 

place where is out of the reach of people and no one can pass by or under it. 

2.  Technical Specifications   

l

  DMX Control: 15 channels  

l

  Motorized focus via DMX control  

l

  Operation Modes: DMX, Master/Slave, Sound Active 

l

  Built-in programs under Master/Slave triggered by music 

l

  Smooth 0

100% dimming and variable strobe speeds  

l

  One rotating gobo wheel with seven gobos and white  

 

Please read the instructions carefully as they include important 
information about installation, usage and maintenance. 

Summary of Contents for MS550

Page 1: ... 2 Technical Specifications 3 How To Set The Unit 3 1 Control Panel 3 2 Gobo Wheel 3 3 Main Functions 3 4 Home Position Adjustment 4 Control By Universal DMX Controller 4 1 DMX 512 Connection 4 2 DMX Address Setting 4 3 DMX 512 Configuration 5 Troubleshooting 6 Fixture Cleaning ...

Page 2: ...pose the unit to rain or moisture Do not open the unit within five minutes after switching off The housing and lenses must be replaced if they are visibly damaged This lighting fixture is for professional use only it is not designed for or suitable for household use The product must be installed by a qualified technician in accordance with local territory regulations The safety of the installation...

Page 3: ...unctions l DMX IN DMX 512 link use 3pin XLR cable to link the fixture and the DMX controller l DMX OUT DMX 512 link use 3pin XLR cable to link the next fixture l Fuse T 6 3A Protects the unit from over voltage or short circuit l MAINS IN PowerCON connection to mains power supply l MAINS OUT PowerCon loop connection for main power supply to the next unit 3 2 Gobo Wheel 3 3 Main Function To select a...

Page 4: ...E Rbutton to confirm To go back to the functions without any changes press the MENU button again Press and hold the MENU button for one second or wait for one minute to go back to the main menu Slave Mode To select the Master Slave Mode press the ENTER button to confirm Press the UP and DOWN button to select Slave 1 or Slave 2 Press the ENTER buttons to confirm To go back to the functions without ...

Page 5: ...thout any changes press the MENU button again Press and hold the MENU button for one second or wait for one minute to go back to the main menu Display Inverse To select Display Inverse use the UP DOWN buttons to select No normal display or Yes inverse display press the ENTER button to confirm To go back to the functions without any changes press the MENU button again Press and hold the MENU button...

Page 6: ... XLR plug and plug it in the DMX output of the last unit 4 1 2 Connect the units together in a daisy chain using the XLR plug from the output of the unit to the input of the next unit The cable can not branched or split to a Y cable DMX 512 is a very high speed signal Inadequate or damaged cables can easily corrupt the signal 4 1 3 The DMX output and input connectors are a pass through type to mai...

Page 7: ...unter clockwise index 0 360 128 189 Counter clockwise Fast Slow 190 193 Stop 194 255 Counter Slow Fast 8 0 7 No Prism effedt 8 255 Prism effedt 9 0 127 Counter clockwise index 0 360 128 189 Clockwise Fast Slow 190 193 Stop 194 255 Clockwise Slow Fast 10 0 255 Iris MAX MIN 11 0 255 Focus 12 0 7 Blackout 008 125 Shutter open 16 131 Strobing Slow Fast 132 139 Shutter open 140 181 Shutter slow open fa...

Page 8: ...X desk check the address settings and DMX polarity 3 Try another DMX controller 4 Check if the DMX cables run near or run alongside high voltage cables that may cause damage or interference to DMX signal C No response to the sound 1 Make sure the unit is not receiving a DMX signal 6 Fixture Cleaning The cleaning of external optical lenses and or mirrors must be carried out periodically to optimize...

Reviews: