background image

 

13- 

  6. DMX512 Connections   

The DMX512 is widely used in intelligent lighting control, with a maximum of 512 channels.   

 

1.  Connect the fixture together in a “daisy chain” by XLR plug cable from the output of the 

fixture to the input of the next fixture. The cable cannot be branched or split to a “Y” 

cable. Inadequate or damaged cables, soldered joints or corroded connectors can 

easily distort the signal and shut down the system 

2.  The DMX output and input connectors are pass-through to maintain the DMX circuit 

when one of the units’ power is disconnected. 

3.  At last fixture, the DMX cable has to be terminated with a terminator to reduce signal 

errors. Solder a 120-ohm 1/4W resistor between pin 2(DMX-) and pin 3(DMX+) into a 

3-pin XLR-plug and plug it in the DMX-output of the last fixture. 

4.  Each lighting fixture needs to have an address set to receive the data sent by the 

controller. The address number is between 0-511 (usually 0 & 1 are equal to 1). 

5.  3 pin XLR connectors are more popular than 5 pins XLR. 

3 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)   

5 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+), 

  Pin4/5: not used 

 

2- 

1. Safety  Introductions   

 

 

WARNING 

 

 

y

  Please keep this User Guide for future consultation. If you sell the unit to another user, 

be sure that they also receive this instruction booklet. 

y

  All fixtures are intact from the manufacturer, please operate follow up the user manual, 

artificial fault are not under guarantee repair. 

y

  Unpack and check carefully that there is no transportation damage before using the 

unit. 

y

  The unit is for indoor use only. Use only in a dry location. 

y

  Do install and operate by operator. 

y

  Use safety chain when fixes the unit. Don’t handle the unit by taking its head only, but 

always by taking its base. 

y

  The unit must be installed in a location with adequate ventilation, at least 50cm from 

adjacent surfaces.   

y

  Be sure that no ventilation slots are blocked, otherwise the unit will be overheated. 

y

  Before operating, ensure that the voltage and frequency of power supply match the 

power requirements of the unit. 

y

  It’s important to ground the yellow/green conductor to earth in order to avoid electric 

shock. 

y

  Maximum ambient temperature TA : 40

. Don’t operate it where the temperature is 

higher than this. 

y

  Don’t connect the device to any dimmer pack. 

y

  First run, there will be smoke or smells, and all disappearing a few minutes later. 

y

  Make sure there are no flammable materials close to the unit while operating, as it is 

fire hazard. 

y

  Look over power wires carefully, replace immediately if there is any damage. 

y

  Never run on for a long time lest shortening lifespan. 

y

  Avoid any inflammable liquids, water or metal objects entering the unit. Once it happen, 

cut off the mains power immediately. 

y

  Do not operate in dirty and dusty environment, also cleaning fixtures regularly. 

Please read the instructions carefully which includes important 

information about the installation, operation and maintenance. 

Summary of Contents for Stage Par 220

Page 1: ...15 Innovation Quality Performance Stage Par 220 Order Code ELUM006 User Manual Please read the instructions carefully before use ...

Page 2: ...blems check the pins on connectors or on PCB of the fixture or the previous one 4 Try to use another DMX controller 5 Check if the DMX cables run near or run alongside to high voltage cables that may cause damage or interference to DMX interface circuit 1 Wrong DMX address in the fixture Set the proper address D No response to the sound 1 Make sure the fixture does not receive DMX signal 2 Check m...

Page 3: ...erate follow up the user manual artificial fault are not under guarantee repair y Unpack and check carefully that there is no transportation damage before using the unit y The unit is for indoor use only Use only in a dry location y Do install and operate by operator y Use safety chain when fixes the unit Don t handle the unit by taking its head only but always by taking its base y The unit must b...

Page 4: ...arest authorized technical assistance center y Disconnect the mains power if the fixture is not used for a long time y Do use original packing materials once transport it again y Do not look directly at the LED light beam while the fixture is on y Possibly hazardous optical radiation emitted from this product Installation The unit should be mounted via its screw holes on the bracket Always ensure ...

Page 5: ... Slave1 or Slave 2 on the second unit to get contrast movement to each other even if you have two units only 4 2 DMX Controller Use universal DMX controller to control the units you have to set DMX address from 1 to 512 channel so that the units can receive DMX signal Press the MENU button up to when is showing on the display Pressing ENTER button and the display will blink Use DOWN and UP button ...

Page 6: ... color Press the MENU button up to when is shown on the display Pressing the ENTER button and use the DOWN and UP buttons to select or or strobe press the ENTER button to confirm and use the DOWN and UP buttons to adjust the value between 0 and 255 once selected press the ENTER button to setup or automatically exit menu mode without any change after one minute To go back to the last function witho...

Page 7: ...wn on the display Pressing the ENTER button and the display will blink Use the DOWN and UP buttons to select display always on or display off 20 seconds after exit menu mode Once selected press the ENTER button to setup or exit menu mode without any change after one minute Back to the functions without any change press the MENU button again Display Inverse Press the MENU button until is blinking o...

Page 8: ...fade if you select the color or fade mode press the ENTER button to confirm and use the DOWN and UP buttons to select color 1 10 or fade speed speed 1 slow speed 2 middle speed 3 fast Once selected press the ENTER button to setup or automatically exit menu mode without any change after one minute To go back to the last function without any change press the MENU button 8 Dimmer Mode Press the MENU ...

Reviews: