46
GB
2. Direct connection to mechanical
extractor
____________________________
The transition piece is not supplied.
____________________________
Make sure the cabinet air intake is not
blocked.
____________________________
When the cabinet is connected directly to a
ventilation duct the whole room is ventilated
through the drying cabinet.
1 Place the supplied collar
(4)
over the hole
in the top of the cabinet, insert the screws
and secure the collar.
2 Connect the flexible hose
(3)
to the collar.
Connect the other end of the hose to the
transition piece
(2),
then secure this over
the exhaust vent in the room.
ELECTRICAL SUPPLY
The drying cabinet must be connected to a
220–230 V, single-phase supply at 50–60 Hz,
via an earthed wall socket.
The drying cabinet is supplied ready for con-
nection with a power cord and earthed plug.
____________________________
The drying cabinet must be connected to an
earthed wall socket using the power cord
supplied.
____________________________
The socket must be positioned so that the
appliance can be easily unplugged if neces-
sary.
____________________________
Check that the electrical supply matches the
data on the rating plate and that the supply
is earthed correctly according to the relevant
standard. We recommend that the supply is
fitted with a residual current device.
____________________________
1. Damp air out
2. Transition piece (not supplied)
3. Flexible hose
4. Collar
5. Air intake
3
4
2
5
1
4
___________________________________
The socket must have its own fused circuit.
____________________________
The manufacturer will not accept any respon-
sibility if electrical connections are not made
as described in this user manual.
____________________________
NOTE!
A replacement power cord should only be fit-
ted by a qualified electrician!
____________________________