21
N
Parameter
Min.
Default
Max
Notes
20
Switchbd button
0
0
255
If the entrance panel is a secondary panel and parameter 19 = 1,
when the direct call button with the same hardware code as the
code programmed in this parameter is pressed, the entrance panel
substitutes the called number with the entrance panel number (pa-
rameter 3) and sends the call on the serial line to the main panel /
main switchboard.
21
Audio Active
0
1
1
1
= The entrance panel activates automatically when the audio line is
charged and the audio voltage is less than 7V
0
= the entrance panel does not activate
22
Pre-code digits
1
4
4
Number of digits used for the pre-code (par. 04)
23
Conv.Duration
0
120
1800
Conversation duration in seconds. When the set time has elapsed the
entrance panel terminates the call.
24
Tone Duration
0
1
255
Interphone ringtone duration in seconds (CH line activation).
25
Answer time
1
30
1800
Time in seconds waiting for answer from the receiving interphone.
When the time elapses the panel terminates the call
26
Funct.1 Time
1
1
255
F1 function (F1 line) activation duration in seconds
Check that the set times are compatible with the devices con-
nected to the corresponding outputs of the power supply.
27
Funct.2 Time
1
1
255
F2 function (F2 line) activation duration in seconds
Check that the set times are compatible with the devices con-
nected to the corresponding outputs of the power supply.
28
Lock time
1
1
255
Lock (SR line) activation duration in seconds
Check that the set times are compatible with the devices con-
nected to the corresponding outputs of the power supply.
29
Enab.Up Window
0
1
1
Enables the “initial user” - “final user” filter
also for commands transferred from terminal 1
to terminal 6 of the entrance panel (0=No, 1=Yes).
30
Datalogger (R9)
0
0
1
1 =
Activates the panel datalogger.
The datalogger records the transfer of messages over the digibus
line. To access the datalogger press
R
+
9
WXYZ
31
View debug
0
0
1
1 =
activates debug messages displayed from the entrance panel.
32
Min LCD Lux (%)
0
5
100
Brightness of the LCD / keypad backlight LEDs and additional mo-
dules with the entrance panel in standby
33
Max LCD Lux (%)
0
50
100
Brightness of the LCD / keypad backlight LEDs and additional mo-
dules when the entrance panel is active
34
TLC Lux (%)
0
25
100
Brightness of the camera lighting LEDs
35
Seconds [0,59] (entrance panel in-
ternal clock)
0
0
59
Seconds setting of the entrance panel internal clock.
36
Minutes [0,59] (entrance panel inter-
nal clock)
0
0
59
Minutes setting of the entrance panel internal clock.
37
Hours [0,23] (entrance panel internal
clock)
0
0
23
Hours setting of the entrance panel internal clock.
38
Days of the month (entrance panel
internal clock)
1
1
31
Day of the month setting of the entrance panel internal calendar.
39
Month [1,12] (entrance panel internal
clock)
1
1
12
Month setting of the entrance panel internal calendar.
40
Year (internal clock entrance panel)
2008
2008
2099
Year setting of the entrance panel internal calendar.
41
Day setting [0,6] (internal clock en-
trance panel)
0
0
6
Day of the week setting of the entrance panel internal calendar.
0 = Sunday
42
External volume
0
30
63
Volume of the entrance panel loudspeaker signal. See paragraph he-
aded ”ENTRANCE PANEL VOLUME ADJUSTMENT”
43
Internal volume
0
30
63
Volume of the entrance panel microphone signal See paragraph he-
aded ”ENTRANCE PANEL VOLUME ADJUSTMENT”
44
Balance
0
21
63
Balance of the telephone fork circuit See paragraph headed ”EN-
TRANCE PANEL VOLUME ADJUSTMENT”
45
F1 Code
0
0
99999999
Code for activation of function F1
46
F2 Code
0
0
99999999
Code for activation of function F2
EN