22
N
Parameter
Min.
Default
Max
Notes
47
1 Memory Num.
0
0
99999999
Quick call number associated with the button “
”.
0
= disabled
48
2 Memory Num.
0
0
99999999
Quick call number associated with the button “
”.
0
= disabled
49
Ext.1 Address
0
0
99999999
Address of external transponder reading device 1
50
Ext.2 Address
0
0
99999999
Address of external transponder reading device 2
51
Ext.3 Address
0
0
99999999
Address of external transponder reading device 3
52
Ext.4 Address
0
0
99999999
Address of external transponder reading device 4
53
Ext.5 Address
0
0
99999999
Address of external transponder reading device 5
54
Ext.6 Address
0
0
99999999
Address of external transponder reading device 6
55
Ext.7 Address
0
0
99999999
Address of external transponder reading device 7
56
Ext.8 Address
0
0
99999999
Address of external transponder reading device 8
57
Tx Key
0
0
3
0
= does not transmit the key;
1
= transmits the key if it is in the entrance panel database
2
= transmits the key if it is not in the entrance panel database
3
= always transmits the key
58
Request Passw
0
0
1
1
= requests password confirmation from the transponder reading
device
59
Tx UP / Down
0
1
1
0
= transmits the key on interphone cable riser serial line (UP)
1
= transmits the key to the main entrance panel / switchboard (DOWN)
60
Hidden Paras
0
0
50
Typing 27 enables the display and programming of parameters 61 –
67
61
Mon. Off Time
0
30
1000
Monitor power-off timeout.
The programmed value is multiplied by 10ms, therefore if Mon. Off
Time = 30 then the timeout = 300ms
62
Transit Time
0
5
1000
Maximum transit time in minutes
63
Command Rep.(+)
0
388
65535
Repetition of special commands
64
Restart Time(h)
0
0
99999999
NOT USED
65
Factory reset.
0
0
99999999
Typing the code 31830988 resets the parameters to their default
values.
66
Flash sector reset
0
0
26
Erases the flash sector indicated from 1 to 26.
IMPORTANT! Improper use of this parameter can damage the en-
trance panel or cause malfunctions!
67
Number of keys from keypad
0
100
2000
Maximum number of keys insertable from keypad
If the parameter is 0, the keys from keypad are disabled.
EN