3
The 4-wire video-intercom kit can easily be installed. It consists of 2
monitors with 4" flat screen powered by two transformers connect-
ed to the A.C. network, one entrance panel “8000” with 1 push-but-
ton, CCD camera and speech unit.
This installation may be expanded by adding extra monitors
and/or interphones, a call repeater relay and other useful
accessories may be supplied on request.
OPERATING PRINCIPLE
Carry out connections as described in this leaflet. When entrance
panel push-button is pressed, a call signal is heard and the monitor
comes on immediately,showing a clear image of the caller.
Lift handset to communicate with caller and if required operate the
electric lock by pressing the push-button with the key symbol.
The monitor turns off automatically after about 30".
The installation can be switched on from the inside by pressing the
push-button with the
symbol, thus allowing an external view
when required.
TECHNICAL CHARACTERISTICS OF MONITOR (ART. 63M7).
-
Surface wall-mounting housing in ABS plastic, available in white,
white/black or black.
- Back plate and fixing screws for wall mounting (supplied in pack-
ing).
- CRT with 4" flat screen.
- Electronic circuit on interchangeable card.
- Standard CCIR, 625 lines, 50 images (Standard EIA on request).
- 4MHz
pass
band.
- Input signal 1-2Vpp on 75 Ohms.
- Operating temperature: 0° C + 40° C.
- Built-in adjustable electronic chime.
- 3-position variable chime volume adjustment.
- Brightness
control
-
Contrast control
- Push button
for electric lock release .
- Auto-switching
push-button
.
-
Push button
for auxiliary functions (stair-light, etc.).
- 15V A.C. supply voltage
- Camera supply output
- Dimensions:
204x220x71
- Weight: Kgs. 1.5 without packing.
TECHNICAL CHARACTERISTICS OF CAMERA (ART. 63U7/V)
- CCD 1/4" sensor
- 3,7 mm F4.5 lens with fixed focus
- Brightness automatic control
- Video signal standard CCIR, 625 lines, 50 images (standard EIA
on request)
- Video output voltage 1Vpp on 75 Ohms
- Operating temperature -5° +50° C.
-
Infrared subjet lighting.
-
Name-tag lighting by means of LED diodes.
- Built-in speech unit
- Removable terminal block for connection
- 12V D.C. 150mA supply provided by monitor.
- Dimensions: 120x80x25 mm
- Weight: Kgs. 0.6 without packing.
TECHNICAL CHARACTERISTICS OF TRANSFORMER (Art. 832/030)
- 4 -Module DIN housing in ABS plastic
- 230V 50Hz supply voltage (other voltages on request)
- 15V A.C. 30VA output voltage
- Internal protectedion against short-circuits with PTC
- Dimensions: 120x80x25 mm
- Weight: Kg. 0.76 without packing.
MONITOR INSTALLATION
Install monitor far from sources of heat and light.
Fig. 1 - Fix the monitor hooking plate to the wall (its base mounted
at 1.40 m. from floor level).
Fig. 2 - Carry out connections on monitor terminal block by following
drawing on page 9 or version of basic diagram on pages 10-
14.
After connecting cables to terminal block, insert monitor
following arrows 1 and 2.
Fig. 3 - Slide “A” adjusts the call volume; knob “B” adjusts bright-
ness.
Knob “C” is to adjust the colour;
push-button “D”
operates electric lock;
push-button “E”
is used for auxiliary functions (stair-light, etc.).
push-button “F”
is used to switch on installation from the monitor;
Fig. 4 -
It is possible to change this monitor into a desk version by
using proper transformation desk kit Art. 6610.
NOTES:
We guarantee the maximum performance of this system if used in
conjunction with special cable supplied (30m), including connection of
12V A.C. 10 VA electric lock.
If longer distances up to max 100m are required, increase cable sec-
tion. Use coaxial cable type RG59.
ENTRANCE PANEL FOR VIDEO DOOR ENTRY SYSTEMS
INSTALLATION PANEL ART. 8901/L2 (8902/L2)
Fig. 5 - Remove the flush-mounted back box from the panel.
Flush-mount the back box upper part at an advisable height
of 1,65 m. from the floor level.
Fig. 6 - Remove front plate as follows (N.B. Screw in base has
already been loosened.):
1- Pull front plate downwards.
2- Detach panel by pulling its lower edge outwards. To fix
front plate again, carry out above operations in the opposite
sequence. Retighten screw on lower border with a screw-
driver, detail E.
Accomplish the panel closing by using the screw type key,
detail F.
Fig. 9 - To reach name-tag, remove name-tag holder from the back
as shown in drawing.
Plate dimensions: 101x271 mm (L x H)
Back box dimensions: 89x248x50 mm. (L x H x D)
The panel may be installed also in the surface wall-mounted version
by using frames with rainproof cover Art. 9212 (Fig. 7) and surface
wall-mounted back boxes Art. 9312 (Fig. 8).
Door entry panel dimensions: 118x290x68 mm (L x H x D)
INSTALLATION OF SUPPLY TRANSFORMER
4-DIN module supply transformer Art. 832/030 may be wall mounted
with long fixing screws (supplied) or on a box equipped with DIN sup-
port. It is advisable to connect supply network with a double pole
fused isolator. This transformer is equipped with thermic protectedion
(PTC) so that, in the event of a short-circuit to the secondary supply,
the protectedion circuit removes the 15V secondary voltage until the
fault is rectified.
After cutting off power supply to the primary and after eliminat-
ing the short-circuit, it is necessary to wait for a few minutes to
allow cooling of the protectedive device, so that the transformer
may start normal operation again.
FAULT-FINDING (can be solved by users):
MONITOR OFF
Check that transformer has been conneoted correctly to mains sup-
ply. Voltage on terminals 11 and 12 of monitor shouid be of 15V.
MONITOR ON WITHOUT PICTURE:
Check that cables between monitor and camera are wired properly
and that there are not interruptions and/or short circuits.
SCREEN.WITH ONE OR TWO HORIZONTAL BARS AND/OR DIS-
TORTED PICTURES.
Check that supply voltage to terminals M and 1 of camera is not less
than 13V. If installation still does not work, contact our maintenance
department or specialized technicians.
GB