GB
6/32
Art. 68TC/K, 68TU/K
SPEECH UNIT
ART. 68TU/K93
Description
Art. 68TU/K93 is an audio speech unit for use with 2-Wire video kits. It is
equipped with an input which allows the connection of an outdoor CCTV ca-
mera. It can only be fitted to Art. 13K1 entrance panels in the 1300 series.
Speech unit (Art. 68TU/K93) technical specifications
- Operating temperature from - 5° to + 45° C.
- Subject lighting by means of infrared LEDs
- Name-tag lighting through LEDs
- Built-in speech unit
- Removable terminal block
-
Input for video signal from an outdoor camera.
- Monitor call push-button.
- Output for control of lighting floodlight by relay type 0170/101
-
Local door release control from entrance panel.
-
Adjustable lock activation time (from 0 to 30 seconds).
- Supply voltage from the bus.
- External dimensions: 80x120x25 mm.
Speech unit (Art. 68TU/K93) controls
The following controls are located on the back of the speech unit:
Fig. 1
Fig. 2
LED CH2
12V
Lock activation
time
External
volume
Internal
volume
Camera activation
time
Camera terminals type 68TU/K, 68TC/K
CL, M)
Connection for relay type 0170/101 for additional floodlight.
(for switching on illumination in the camera's observation zone)
It is activated for the time the camera is on.
CA, M)
Connection for additional lock push-button.
PA, M)
Connection for "open door" sensor. The sensor must be a nor-
mally open contact which closes when the door is open.
B1, B2) BUS line
S-, S+) Output for electric lock supply voltage (12V
).
V)
Connection for video signal from an outdoor camera.
*
The panel supplies a current peak IT> 1A for 10 mS, followed by a hold
current I
M
= 200mA for the entire duration of the lock control.
*
ENTRANCE PANEL/CAMERA identification code
If more cameras/entrance panels are installed on the building it is necessary
to identify the cameras with a different code. The identification code is as-
signed by inserting the jumpers in the contacts as shown on the figure.
1st camera
IT=0
(Default)
2nd camera
IT=1
OPERATING DWELL TIME
The monitor, camera, door lock and auxiliary services mut operate accor-
ding to the following intermittent cycles.
Monitor and camera activation cycle:
max. 90 seconds activated, 90 seconds deactivated
Door lock cycle:
max. 1 second activated, 5 seconds deactivated
Auxiliary service cycle:
max. 90 seconds activated, 90 seconds deactivated
Microphone
Name tag lighting
LED
1st push-button
2nd push-button
Name tag lighting
LED