SAFETY INSTRUCTIONS FOR INSTALLERS

- Carefully read the instructions on this leaflet: they give important information on the safety, use and maintenance of the instal-

lation. 

- After removing the packing, check the integrity of the set. Packing components (plastic bags, expanded polystyrene etc.) are

dangerous for children. Installation must be carried out according to national safety regulations.

- It is convenient to fit close to the supply voltage source a proper bipolar type switch easy accessible with 3 mm separation (min-

imum) between contacts.

- Before connecting the set, ensure that the data on the label correspond to those of the mains. 
- Use this set only for the purposes designed, i.e.for electric door-opener systems. Any other use may be dangerous. The man-

ufacturer is not responsible for damage caused by improper, erroneous or irrational use. 

-

Attention:

to avoid hurting himself, this appliance must be fixed to the soil/wall according to the installation instructions. 

- Before cleaning or maintenance, disconnect the set.
- In case of failure or faulty operation, disconnect the set and do not open it. 
- For repairs apply only to the technical assistance centre authorized by the manufacturer.
- Safety may be compromised if these instructions are disregarded. 
- Do not obstruct opening of ventilation or heat exit slots and do not expose the set to dripping or sprinkling of water. 
- Installers must ensure that manuals with the above instructions are left on connected units after installation, for users' infor-

mation. 

- All items must only be used for the purposes designed. 
- The installer must make sure that the information for the user be present with the appliances.
- This leaflet must always be enclosed with the equipment.

Directive 2002/96/EC (WEEE)

The crossed-out wheelie bin symbol marked on the product indicates that at the end of its useful life, the product must be hand-
led separately from household refuse and must therefore be assigned to a differentiated collection centre for electrical and elec-
tronic equipment or returned to the dealer upon purchase of a new, equivalent item of equipment.

The user is responsible for assigning the equipment, at the end of its life, to the appropriate collection facilities. Suitable diffe-
rentiated collection, for the purpose of subsequent recycling of decommissioned equipment and environmentally compatible treat-
ment and disposal, helps prevent potential negative effects on health and the environment and promotes the recycling of the
materials of which the product is made. For further details regarding the collection systems available, contact your local waste
disposal service or the shop from which the equipment was purchased.

Risks connected to substances considered as dangerous (WEEE).

According to the WEEE Directive, substances since long usually used  on electric and electronic appliances are considered dan-
gerous for people and the environment. The adequate differentiated collection for the subsequent dispatch of the appliance for
the recycling, treatment and dismantling (compatible with the environment) help to avoid  possible negative effects on the envi-
ronment and health and promote the recycling of material with which the product is compound.

Summary of Contents for 8017

Page 1: ...1 70E RL 00 11 2007 Il prodotto è conforme alla direttiva europea 89 336 CEE e successive Product is according to EC Directive 89 336 EEC and following norms CONNECTION MANUAL KEYPAD ENCODED WITH TOUCH KEYS ALPHANUMERICAL ...

Page 2: ... onto PC by means of the specific interface The control unit featuring total autonomous use can also be interfaced with the Digibus systems and or a PC both for code programming and the remote management of an entire access control system made in ITALY R CN4 PROGRAM T2 4 T3 T4 T1 S4 S3 S2 RB RA 1 4 5 Art 8017 RESET Top terminal boards Left Code reader contact PROBE Right Encoded digital codes Touc...

Page 3: ...locks but at specific time intervals T1 Positive to connect to probe of touch number 1 The touch reader is connected between this terminal white wire and earth black wire Multiple readers can be connected in parallel all with the same functions T2 Positive to connect to probe of touch number 2 The touch reader is connected between this terminal white wire and earth black wire Multiple readers can ...

Page 4: ... In the case of programming accessory parameters by pressing as in point 5 above the following options can be set Activation of the key only on some of the 4 probes readers By default each key is valid on all 4 reader inputs touch Modification of key priority between 0 and 15 currently set at 7 This second function only serves for special management modes timed by computerised systems 7 To set the...

Page 5: ... individual users modify priority levels and update download upload utilities KEY PROGRAMMING AND OPERATION VIA THE KEYPAD The control unit enables in addition to the use of touch keys management of an access point via the KEYPAD This can memo rise 100 different 8 digit codes usable to activate relay output n 1 Operation and programming of these codes is the same as in the case of the digital pane...

Page 6: ... the simultaneous activation of output AUXILIARY 4 based on set times In this case for example on output 1 the relative lock can be activated for 1 second and the stair light for 2 minutes 2 On activation of the corresponding output activates delivery on the serial line of the relative associated Digibus code for acti vation of remote relays 4 Activates the ON OFF mode On the first reading of a ke...

Page 7: ...ut 4 and delivery of command on serial line for remote control 8 8 Combined mode Uses 2 touchkeys for output 1 separate ON and OFF 16 16 As per 0 but the programmed times are in minutes instead of seconds max 255 minutes 17 16 1 As above but also activates output 4 with specific times 32 32 Activates the request of the output number to be activated 33 32 1 As per 32 1 Activates the request of the ...

Page 8: ...n cycles For each of these it memorises the type of operation some accessory information and the time of activation if the clock is fitted otherwise based on an internal coun ter To view the data it must be downloaded onto PC by means of the interface 6952 and the software supplied The procedure is similar to that performed for programming with the same software started up in view accesses mode Ty...

Page 9: ...tion and deletion of key list from keypad CONNECTION OF PC FOR DATA DOWNLOAD UPLOAD This is performed by means of the specific interface type 6952 connected to the COM port of the PC as shown in the example below NB in this case the panel is type 8017 made in ITALY R CN4 PROGRAM T2 4 T3 T4 T1 S4 S3 S2 RB RA 1 4 5 Art 8017 RESET Art 6952 Interfaccia seriale serial interface made in ITALY R The conn...

Page 10: ...ALARM 51 F_ACTIV_DEVICE 52 F_DISACTIVE_DEVICE 53 CALL_PANEL 33 audio call from panel to interphone CALL_SELFST_PANEL 49 video call from panel to interphone CALL_PANEL TLC 161 similar to above but for intercommunicating calls CALL_PANEL INTERC 177 CALL_PANEL TLC INTERC 73 CALL_SELFST_PANEL_TLC 74 LOCK_BACK 75 lock release backwards ENTER_PRG 120 when setting the interphone prog NOOPEN_LOCK 123 key ...

Page 11: ... you wish that one key activates another exit example exit no 3 you must modify the first number after the code 0 by pressing key several times values from 1 to 7 will be displayed in sequence and then will return to 0 As a consequence of this value when inserting relevant code the exit will be activated accor ding to the table here below 0 The exit will be enabled by default according to the para...

Page 12: ...d if these instructions are disregarded Do not obstruct opening of ventilation or heat exit slots and do not expose the set to dripping or sprinkling of water Installers must ensure that manuals with the above instructions are left on connected units after installation for users infor mation All items must only be used for the purposes designed The installer must make sure that the information for...