GENERAL OPERATION:
The board , (equipped with an alphanumerical display with 2 lines x 16 characters) manages up to 4 different access points for
“TOUCH KEY” type readers. Each access point can activate a different relay connected directly to the board “ locally” (the first
output already has an “on-board” relay), and simultaneously/when necessary to enhance safety, an external relay connected
“remotely” by means of a serial bus (with type 170D-170F or similar).
Each of the 4 output (to relays) can operate in various modes (timed, on/off, combined, etc) with time intervals settable from 1
and 255 seconds or from 1 minute to 255 minutes.
The control unit memorises up to
500
“TOUCH KEYS“ (expandable on request to over 2000 users), managing different priorities
and permissions for each user (on the 4 outputs).
At the same time,
100
different 8-digit digital codes can be memorisedto be used as passwords, directly on the control unit key-
pad.
If equipped with a clock module, the control unit also enables each opening operation to be recorded (within an internal list of
500 cycles). This list can be downloaded if required onto PC by means of the specific interface.
The control unit, featuring total autonomous use, can also be interfaced with the “Digibus” systems and/or a PC both for code
programming and the remote management of an entire access control system.
made in ITALY
R
CN4
PROGRAM
T2
4
T3
T4
T1
S4
S3
S2
RB
RA
1
4
5
Art. 8017
RESET
Top: terminal boards. <- Left: Code reader contact
(“PROBE”). Right: Encoded digital codes (“Touch keys”). ->
DESCRIPTION
The control module type 8017 is a component for the modular system of panels series 8000. The entrance panels may be pre-
set for the flush-mounted or surface wall-mounted installation, possible provided with rainproof cover. The entrance panel may
be installed in the flush-mounted version by using the module holder frames type 8D81, 8D82, 8D83, 8D84, and in the surface-
wall mounted version using, besides the abovementioned module holder frames, the proper surface wall-mounted back box (type
9411, 9412, 9413, 9414) (See fig. 1).
The 8017 module is equipped with an output with relay for the lock release and 3 (additional) open-collector output for the con-
trol of relay type 170/001. Module require an power supply Art. 6582
ENTRANCE PANEL SERIES 8000, FLUSH-MOUNTED VERSION.
ENTRANCE PANEL SERIES 8000, SURFACE WALL-MOUNTED VERSION.
Fig. 1
Art. 8D8x
Art. 909x
Art. 92xx
Art. 8D8x
Art. 94xx
Art. 92xx