background image

IT

38

40540 - 40542 - 40540.D - 40547

• WEEE - User information. 

The crossed bin symbol on the appliance or on its packaging indicates 

that the product at the end of its life must be collected separately from other waste. The user must 
therefore hand the equipment at the end of its life cycle over to the appropriate municipal centres for the 
differentiated collection of electrical and electronic waste. As an alternative to independent management, 
you can deliver the equipment you want to dispose of free of charge to the distributor when purchasing 
a new appliance of an equivalent type. You can also deliver electronic products to be disposed of 
that are smaller than 25 cm for free, with no obligation to purchase, to electronics distributors with a 
sales area of at least 400 m

2

. Proper sorted waste collection for subsequent recycling, processing and 

environmentally conscious disposal of the old equipment helps to prevent any possible negative impact 
on the environment and human health while promoting the practice of reusing and/or recycling materials 
used in manufacture.

• Regulatory compliance. 

 

EMC directive. RoHS directive.  
Standards EN 55032, EN 55035, EN 62368-1, EN IEC 63000.  
REACH (EU) Regulation no. 1907/2006 – art.33 The product may contain traces of lead.

• Warnings for the user 

Do not open or tamper with the appliance. 
In the event of faults, contact specialized personnel.

Maintenance 

Clean using a soft cloth. 
Do not pour water onto the appliance and do not use any type of chemical product.

• Installation must be carried out by qualified persons in compliance with the current regulations regarding the installation 

of electrical equipment in the country where the products are installed. 

• For further information, visit www.vimar.com

Summary of Contents for Vimar 40540

Page 1: ...Voxie 40540 40542 40540 D Voxie Due Fili Plus handset entryphone Use and Configuration Manual 40547 Voxie Due Fili Plus hands free entryphone...

Page 2: ...aging Sending a one way public paging announcement to other hands free devices in the same group only for 40542 and 40547 21 Alert function with dedicated input on terminals AL M only for 40542 and 40...

Page 3: ...nting Voxie handset entryphone for Due Fili Plus system with 2 push buttons for door lock release and auxiliary service stair light functions teleloop for hearing aids surface mounting 40542 40547 405...

Page 4: ...receipt of a call from entrance panel only if enabled via configuration software or via dip switch with random activation time General apartment intercom call only for 40542 and 40547 mutually exclus...

Page 5: ...y from BUS terminals 1 2 rated voltage 28VDC Ambient class Class A1 indoor use IP30 protection degree Operating temperature 5 40 C indoor use Operating environment humidity 10 80 non condensing Techni...

Page 6: ...ivates the first relay of the Due fili system Aux 1 5 Ringtone volume indicator Ringtone mute Level 1 Level 2 Level 3 6 Signalling red LED Alert rapid flashing 0 1 s on 0 1 s off missed call from swit...

Page 7: ...ble with the configuration software for Alert function only for 40542 reconfigurable to activate the professional firm function only N O b Due Fili Plus bus termination ABC jumper SWITCH TABLE A B C A...

Page 8: ...ng 0 2 s on 4 8 s off door open and automatic lock release active permanently lit with short power off 0 2 s off 4 8 s on 7 Auxiliary activation stair light it activates the first relay of the Due fil...

Page 9: ...tance to the terminals except for the Due Fili Plus bus is 10m N B the functions associated with the LC Local Landing Call input and the CH Open Collector output can be modified via programming For th...

Page 10: ...angular mounting box with 3 modules Vimar 71303 V71703 British standard square mounting box Table mounting with desktop base accessory 40598 Installation Entryphone opening 160 165 cm 120 cm Installat...

Page 11: ...IT 11 40540 40542 40540 D 40547 Note Excessive tightening can cause imperfections in the alignment and operation of the buttons 2A 2B Pb WWYY Pb WWYY 2A 2B...

Page 12: ...IT 12 40540 40542 40540 D 40547 1 2 4 3 Pb WWYY 1 2 Pb WWYY 4 3...

Page 13: ...IT 13 40540 40542 40540 D 40547 5 5...

Page 14: ...CH M 12V 2 1 FP CH M 12V 2 1 FP CH M 12V M AL N 0 N C RISER RISER 2 1 FP CH M 12V 2 1 FP CH M 12V 2 1 FP CH M 12V 2 1 FP CH M 12V Landing call button Indoor station in in out configuration Indoor sta...

Page 15: ...utput 100 mA 0170 101 Relay Ringtone Ringtone power supply 860A Additional ringtone Mains Configurable via configuration software or dip switch N B the ringtone volume adjustment has no effect on the...

Page 16: ...ion The Voxie entryphone is designed to receive calls from Outdoor Stations Indoor Stations and the Reception switchboard It can also make intercom calls to other Indoor Stations and the Reception Swi...

Page 17: ...receipt of a call the white LED located above the lock button flashes Answering a call Lift the handset and answer the call Replace the handset to end the call Press the Talk Listen button to answer t...

Page 18: ...the Indoor Station releases the lock of the last calling entrance panel Lock release After answering a call from an outdoor station the release of the lock on the connected outdoor station can be ope...

Page 19: ...push button for example Press to call the Indoor Station associated with the push button for example During the call the Indoor Station emits a tone in order to signal that the call is being made If t...

Page 20: ...he white LED starts flashing 2 Press the Lock button to make a call to the Reception switchboard During the call the Indoor Station emits a tone in order to signal that the call is being made If the I...

Page 21: ...r Station calls the other devices max 3 within the relevant Group both master and secondary However this can be extended to more than 3 devices using SaveProg N B the function is alternative to paging...

Page 22: ...stem and the entrance panels have been programmed Configurations The entryphone can be configured in the following three ways Simplified programming via entryphone push buttons Dip switch configuratio...

Page 23: ...the programming phase Press and hold down the lock push button for 6 s 2 When the time runs out the indoor station will emit a beep 0 5 s 3 Release the lock push button When the push button is release...

Page 24: ...se the handset and bring it to your ear to listen to the sound feedback emitted by the handset during the programming phase 2 Press and hold down the lock push button for 6 s 3 When the time runs out...

Page 25: ...edback emitted by the handset during the programming phase 2 Press the push button to be programmed and hold it down for at least 6 s 3 When the entryphone has emitted a beep release the push button b...

Page 26: ...ush button to be programmed and hold it down for at least 6 s 3 When the entryphone has emitted a beep release the push button being programmed 4 On push button entrance panels press the call button f...

Page 27: ...s until the entryphone emits a first beep followed by a double beep 3 Release the push button being programmed 4 From the entrance panel involved make a call to the indoor station being programmed on...

Page 28: ...the sound feedback emitted by the handset during the programming phase 2 Press the push button you want to reprogramme to its default value and hold it down for at least 6 s 3 After 6 seconds the entr...

Page 29: ...phase 2 Press and hold down the lock push button for 6 s When the time runs out the indoor station will emit a beep 0 5 s 3 Continue to hold down the door lock push button After 2 s more the indoor st...

Page 30: ...IT 30 40540 40542 40540 D 40547 6s 2 s 2 s beep beep 2 x beep 2 4 3 5 6 7 beep 3 x beep...

Page 31: ...and acoustic only for handset entryphones for confirmation or invalid setting NB the dip switch values are read only when the Config button or the button to configure is pressed once positive feedback...

Page 32: ...001 ID 1 0000 0010 ID 2 0000 0011 ID 3 1100 1000 ID200 1100 1001 switchboard 1 1100 1100 switchboard 4 5 Configure push button to send the lock release control to a specific outdoor station 0100 0001...

Page 33: ...111 0011 0000 disab 14 Dis Enabling the professional firm function that can be activated deactivated by the user 1111 0000 0111 en 1111 0000 0110 disab default 15 Dis Enabling the paging sending repla...

Page 34: ...8 1011 0010 29 0001 1101 79 0100 1111 129 1000 0001 179 1011 0011 30 0001 1110 80 0101 0000 130 1000 0010 180 1011 0100 31 0001 1111 81 0101 0001 131 1000 0011 181 1011 0101 32 0010 0000 82 0101 0010...

Page 35: ...00 1000 122 0111 1010 172 1010 1100 23 0001 0111 73 0100 1001 123 0111 1011 173 1010 1101 24 0001 1000 74 0100 1010 124 0111 1100 174 1010 1110 25 0001 1001 75 0100 1011 125 0111 1101 175 1010 1111 26...

Page 36: ...01 6 0110 7 0111 8 1000 9 1001 10 1010 11 1011 12 1100 13 1101 14 1110 15 1111 Code for relay activation ID ID 69 H relay Code 1 1 A 0001 2 1 B 0010 3 2 A 0011 4 2 B 0100 5 3 A 0101 6 3 B 0110 7 4 A 0...

Page 37: ...U Follow the instructions in SaveProg FWUpdate or WinBoot For updates disconnect the device from the Due Fili bus connect the interface 692I U to the PC first USB port and then to the device then laun...

Page 38: ...t 400 m2 Proper sorted waste collection for subsequent recycling processing and environmentally conscious disposal of the old equipment helps to prevent any possible negative impact on the environment...

Page 39: ...IT 39 40540 40542 40540 D 40547...

Page 40: ...49401591A0_MU_EN 00 2105 Viale Vicenza 14 36063 Marostica VI Italy www vimar com...