Function

Operation

 

Maintenance

Operating instructions

PUROTAP® easy II

Summary of Contents for PUROTAP easy II

Page 1: ...www elysator com Installation Function Operation Maintenance Operating instructions PUROTAP easy II...

Page 2: ......

Page 3: ...description 6 4 2 Dimensions 6 4 3 Performance data 6 5 Operation 5 1 1 Draining spent resin 7 5 1 2 Filling the resin canister 7 5 2 Connection 8 5 3 Commissioning 8 5 4 Combined meter 9 6 Maintenanc...

Page 4: ...4 1 Safety instructions Not drinking water Maximum 60 C Maximum pressure 6 bar not constantly Flow rate max 15 l min 6 bar 15 l min...

Page 5: ...e resin The device has an integral meter that constantly measures and displays fill volume throughput and water quality There is no need for an external power supply and no chemicals are released into...

Page 6: ...d mesh filter 5 Head with immersion pipe 6 PUROTAP LFM 20 combined meter 7 Handle 8 Fine mesh filter 9 Outlet 4 2 Dimensions Dimensions PUROTAP easy II Height 74 0 cm Width 32 5 cm Depth 25 0 cm Weigh...

Page 7: ...n drain valve 4 Open shut off valve 2 5 Flush until no more resin is left in the canister 6 Remove collection bag from the drain and allow to drip 7 Close drain valve and screw round mesh filter with...

Page 8: ...pipe is screwed on tightly 5 2 Connection Connect the device to the raw water at the inlet 1 using an adequately sized hose Connect the outlet 9 to the system to be filled also using a hose The device...

Page 9: ...ogramming the limit ensures that a warning is issued when the ion exchange resin is spent If the set limit is exceeded the backlight flashes red and an acoustic alarm sounds In addition the floating c...

Page 10: ...ptional power supply unit the combined meter does not automatically switch off and cannot be switched off manually If the combined meter has switched off automatically it will automatically restart on...

Page 11: ...e 4 screws on the red cover lift off the cover and insert 3 new AAA LR03 1 5 V batteries Make sure the cover seal is seated properly Refit the cover and secure with the screws Check the device is work...

Page 12: ...nt 7 Spare parts Item no Designation 100 967 PUROTAP easy II complete immersion pipe 100 620 PUROTAP easy II complete head 102 278 PUROTAP LFM 20 combined meter 100 255 PUROTAP easy II O ring for head...