background image

3 x AAA

Set limit for
warning

Limit

Reset 
meter

Flow rate

ON/OFF

Total litres treated

Select either
TDS/µS

Automatic quality monitor

Display:

Keys:

Limit warning signal

Operating the combined meter

Changing the batteries

The combined meter is battery-operated. It measures the flow rate in l/min, the total volume in litres and 
the concentration of dissolved minerals, either in microsiemens or TDS. In addition, a limit can be set for the 
maximum concentration of minerals tolerated in the demineralised water (appliance outlet). The limit and 
overall total can both be reset. 

Change  the  batteries  when  the  battery  warning  symbol 
appears or the display is faint or blank. Undo the 4 screws 
on the front and carefully open the device. Change the bat-
teries. 3 x AAA.

Getting started:

Set the limit to 33 TDS/50 µS/cm.
Before and while filling the heating 
system, press the ON key for indivdual 
measurements every 5-10 litres (3). 
A red LED warns if the cartridge is 
spent (limit reached).
Insert a new cartridge and reset the 
total litres (4).

Each time you touch this key, the boundary value is raised by 6/7 TDS or by 10 µS/cm. Holding down the key 
for 3 seconds resets the boundary value to zero. Programming the boundary value serves as a warning as to 
when the ion exchanger resin is exhausted.

This key can be used to switch at any time between the TDS unit of measurement (Total Dissolved Solids) 
and electrical conductivity. Both are used to measure the concentration of dissolved minerals in the water. 
Most European component manufacturers use the µS/cm unit of measurement (microsiemens).
The water hardness at the outlet of the refill appliance can be calculated using the following rule of thumb:

1 °fH equals approx. 20 µS/cm; 1 °dH equals approx. 35 µS/cm.

1

2

If the ON key is pressed once, the water quality is measured for 10 seconds and compared to the set limit. 
The measured value is shown. If it is above the limit, the LED glows red; if it is below, the LED glows green 
while the measurement is being taken. If required, the measurement can be repeated manually.

Auto mode: 

If the ON key is pressed for a second time, the combined meter begins automatic monitoring. 

The eye symbol appears to indicate that monitoring has been enabled. In auto mode, the meter only takes 
measurements  when  water  is  actually  passing  over  it.  If  the  water  draw-off  is  interrupted,  the  meter 
continues to show the last captured value. While water is being drawn off, the combined meter measures 
the  water  quality  every  10  litres.  If  the  limit  is  exceeded  in  two  successive  measurements,  the  display 
continuously flashes red. This indicates that the ion exchange resin is spent and needs replacing. If the ON 
key is pressed for a third time, the meter exits auto mode.

3

Pressing the reset key for 3 seconds resets the overall total on the meter. This is recommended every time 
the resin is replaced, as it gives a reference point for the remaining capacity of the ion exchange resin.

4