background image

7

 

EMS-115 User Manual 

www.emacoustics.co.uk 

DSP Settings 

 

The EMS-115 requires at the minimum an active low pass filter to function correctly.  The settings below are given 
as a starting point – as the user you are given maximum flexibility to adjust for your taste.  To protect the drive 

unit,  it  is  also  advisable  to  apply  a  high  pass  filter  to  the  system  to  protect  the  EMS-115  drive  unit  from  over-

excursion from frequencies it cannot reproduce.  The higher you raise the high pass filter on an EMS-115, the more 

headroom and overall sound pressure level output there is available.  For most medium-to-high level applications, 

we would recommend a minimum of an 45Hz high pass filter with a 24dB/octave slope to sufficiently protect the 

loudspeaker.    For  higher  SPL  applications,  we  would  recommend  raising  this  filter  –  we  would  stress  that  the 

higher the filter, the safer the loudspeaker will be.  If you are in any doubt over suitable settings for your EMS-115, 

please don’t hesitate to contact EM Acoustics or your local dealer for support and advice. 

 
EMS-115: 

High Pass Filter:   

45Hz, 24dB/Octave Linkwitz-Riley 

 

 

Low Pass Filter:  

125Hz maximum, 24dB/Octave Linkwitz-Riley 

Summary of Contents for EMS-115

Page 1: ...ofer User Manual v1 0 EM Acoustics Loudspeakers Building 74 Dunsfold Park Cranleigh Surrey GU6 8TB UK Phone 44 0 1483 266520 Fax 44 0 1483 275619 www emacoustics co uk ________________________________...

Page 2: ...you 3 Unpacking 3 Declaration of Conformity 3 Product Overview EMS 115 quasi bandpass subwoofer 4 System Set up Safety Considerations 5 Cabling Amplifier selection 6 DSP Settings 7 Maintenance EMS 115...

Page 3: ...it leaves our factory After unpacking your loudspeaker please inspect it carefully for any signs of transit damage If such damage is found please notify the carrier at once to instigate a claim It is...

Page 4: ...ions The EMS 115 is suited to a wide variety of professional audio applications from corporate and theatre use through to small medium scale front of house or nightclub use As with all EM Acoustics su...

Page 5: ...dware When mounting in this way please consider the following Ensure your stand height is locked off and the system is stable Check the weight loading of your poles before attempting to mount the loud...

Page 6: ...t amplifier choice and setup Cabling The EMS 115 is supplied as standard with Neutrik SpeakONTM NL4 connectors wired pin 1 1 It is recommended that the resistance of your cable is less than one tenth...

Page 7: ...filter on an EMS 115 the more headroom and overall sound pressure level output there is available For most medium to high level applications we would recommend a minimum of an 45Hz high pass filter w...

Page 8: ...d bolts holding the drive unit in place and keep them safe ensuring you have collected both the shake proof and flat washers for each bolt Gently lift the drive unit out of its locating hole please ta...

Page 9: ...ng your EM Acoustics loudspeaker Should your EM Acoustics loudspeaker develop a fault please return it freight prepaid in its original packaging along with proof of purchase to your local dealer or to...

Page 10: ...ve recommended below 120Hz 24dB Octave L R CONNECTORS 2 x Neutrik SpeakONTM NL4MPR ENCLOSURE 18mm 3 4 multi laminate Birch plywood rebated screwed glued Finished in impact resistant textured paint ENC...