TABLE OF
CONTENT
P
A
G
E
2
....
3
4
....
....
WARNINGS AND SAFETY INSTRUCTIONS
P1 CONTENT
WARNINGS AND SAFETY INSTRUCTIONS
GENERAL WARNING
This instruction contain general caution information for use in Pool and SPA pump installation
application. Specified Pump model function should be refer to particular manual. Components such
as the filtration system, pumps and heater must be positioned so as to prevent their being used as
means of access to the pool by young children.
This appliance should be installed by qualified electrical personnel
in accordance with National Electrical Code and all applicable
local codes and ordinances.Hazardous voltage can shock , burn,
and cause death or serious property damage. DO NOT use an
extension cord to connect unit to electric supply to reduce the risk
of electric shock .
1
.
The pump should be permanently connected to an individual circuit breaker.
2
.
Pump must be connected to a residual current device (RCD) having a rated residual operating
current notexceeding 30 mA or receptacle with ground fault circuit interrupt (GCFI).
3. Electrical grounding must be connected before connecting to electrical power. Failure to ground all
electrical equipment can cause serious or fatal electrical shock hazard.
4
.
Bonding: Use at least #8 AWG (#6 AWG for Canada) a solid copper conductor, run a continuous wire
from external bonding lug (if available) to the pressure wire connector provided on the electrical
equipment and to all metal parts of swimming pool, spa, or hot tub, and metal piping (except gas
piping), and conduit within 1.5 m (5 ft) of inside walls of swimming pool, spa, or hot tub.
5
.
Never open the inside of the drive motor enclosure. There is a capacitor bank that holds a mains
supply voltage charge even when there is no power to the unit. The voltage should be referred to
the individual pump operation voltage.
6
.
The pump is capable of high flow rates; use caution when installing and programming to limit
pumps performance only.
7
.
Switch OFF pump power before ser vicing and disconnecting the main circuit to the pump.
8
.
Never change the filter control valve position while the pump is running.
RISK OF ELECTRICAL SHOCK
COMPRESS AIR HAZARDOUS
This system enclosed pre-filter / filter and become pressurized.
Pressurized air can cause the Lid to separate which can result in
serious injur y or death.
Pool and spa circulation systems operate under high pressure. When any part of the circulating
system (i.e. lock ring, pump, filter, valves, etc.) is ser viced, air can enter the system and become
pressurized. Filter tank Lid and pre-filter cover must be properly secured to prevent violent
separation. Place pre-filter / filter air relief valve in the open position and wait for all pressure in the
system to be relieved before remove the lib to access the basket for cleaning.
HYPERTHERMIA
SPA water temperature excess 38°C (104°F) may be injurious to
health. Measure water temperature before entering SPA.
Hyperthermia occurs when the internal temperature of the body
reaches a level several degrees above the normal body
temperature of 98.6 °F (37 °C). The symptoms of hyperthermia
include drowsiness, lethargy, and an increase in the internal temperature of the body.
WARNINGS AND SAFETY INSTRUCTIONS P2
STAND CLEAR OF PUMP DURING START-UP
Fo
r a
bo
ve
-g
ro
un
d p
oo
ls
(S
D S
er
ie
s) a
nd p
or
ta
bl
e s
pa
s(
ST S
er
ie
s)
S
D & S
T S
E
R
IE
S
1. SD & SDUS, ST & STUS SERIES CENTRIFUGAL PUMP
OVERVIEW
2. PRODUCT INFORMATION (SD & SDUS)
3. PRODUCT INFORMATION (ST & STUS)
4. IMPORTANT SAFETY INSTRUCTIONS
5.
INSTALLATION
5.1 PIPING
5.2 ELECTRICAL WIRING
6. START UP
7. ROUTINE MAINTENANCE
8.
WINTERIZING
9. TROUBLE SHOOTING
10. REPLACEMENT PARTS
10.2 SDUS SERIES
10.1 SD SERIES
10.3 ST SERIES
11. TERMS OF THE WARRANTY
SUCTION ENTRAPMENT HAZARD
4
....
5
....
7
....
7
....
9
....
10
....
10
....
11
....
12
....
20
....