background image

 

For devices between 900 and 1900 mm, the 
controls are integrated in the device. The 
connectors for the mains and ventilator are 
located underneath the device. You require one 
socket for the power supply. 

 

The customer service must be able to access the 
controls. Please provide two inspection openings 
in the rear walls of kitchen furniture. Covers for 
the inspection openings are included in the scope 
of supply. 

 

 

Electrical connection for recirculation mode 

The controls are located on the rear or on the 
left of the front side, next to the activated 
carbon filters. The connectors for the mains and 
ventilator are located on the ventilator control. 
You require two sockets for the power supply. 

 

Initial operation

 

Press the 

 button, the device must move 

upwards. Once it is in the upper position, you can 
switch on the ventilation. Check all the functions. 
 
 
 
 
 

Press the 

 

button, the device must move 

downwards. 

Should the hood not move, perform an 
initialisation run (see page 6). 
Move the hood several times and observe 
whether the device runs in parallel. 
 

After aligning the device and using for the first 
time, secure it in a suitable place using the 
mounting brackets supplied.  

 

The brackets can be attached to the screws of 
the device cladding or the screws in the side 
parts. Attach the brackets as far down as 
possible. The top of the device is fixed in place 
in the work surface cut-out and can thus not 
move. Should there be too much play here, 
secure here as well to ensure that the device 
remains stable. 
If the downdraft ventilation is aligned in the 
cut-out in the kitchen work surface and if the 
loose cover is exactly flush with the work 
surface in the lower position, you can also 
adhere the cover to the mounting plate. The 
cover must only be adhered to the mounting 
plate and not to the housing. Make sure you 
can still access the adjustable feet to allow 
readjustment at a later date. 
Subsequent minor adjustments can also be 
made using both lifting cylinders. For this, 
the upper cover must be removed. 
The height can be adjusted by undoing the 
fastening nut M10 and turning the setscrew 
with an Allen key.  
The tilt can be set by turning the magnets 
 
 
 
 
 
 
 
 
 

Summary of Contents for Downdraft

Page 1: ...for EMB DOWNDRAFT EXTRACTOR HOOD as of 08 2016 Assembly and operating instructions ...

Page 2: ...xtraction mode Page 3 Installation for recirculation mode Page 3 Assembly of foot extensions Page 4 Assembly Page 4 Electrical connection for extraction mode Page 4 Electrical connection for recirculation mode Page 5 Initial operation Page 5 Notes Page 6 Initialisation run Page 6 Maintenance Page 6 No function Page 7 EMB Edelstahl Möbel Beck Brückenstraße 11 74219 Möckmühl Züttlingen Germany Tel 4...

Page 3: ... together with a gas hob a safety switch is required which only allows the air to be extracted in the upper position Warranty claims cannot be asserted for any damage which results from failure to observe these instructions We reserve the right to make technical changes Before using for the first time Before putting the device into use please note the information below Read the assembly and operat...

Page 4: ...emaining steam and odours from the air The run on function provides the option of having the fan switch off automatically after 15 minutes The extractor fan features a filter cleaning display which reminds you to clean the filters after 30 hours of service After this operating time the power level display flashes After cleaning the filters the button is pressed until the power level display flashe...

Page 5: ... authorised specialist Observe the assembly instructions and local installation requirements Before disposing of the packaging material make sure there are no more accessories in the packaging Check the device for transport damage prior to assembly The user must be informed on how to de energise the device if necessary With extraction mode The exhaust air can be guided in all directions the releva...

Page 6: ...aces towards the cooking area Lift the device into the cut out by turning out the adjustable feet To set the final height place the cover on the device Set the height so that the cover is flush with the work surface Align the device vertically Kitchen work surfaces which are thinner than 34 mm can be prevented from sagging by using thread screws M4x25 which are screwed into the upper frame Connect...

Page 7: ...hood several times and observe whether the device runs in parallel After aligning the device and using for the first time secure it in a suitable place using the mounting brackets supplied The brackets can be attached to the screws of the device cladding or the screws in the side parts Attach the brackets as far down as possible The top of the device is fixed in place in the work surface cut out a...

Page 8: ...down the button for a further 10 seconds The system is lowered slightly and lifted up again during initialisation The initialisation run is then complete Please do not let go of the down button during the initialisation run If you let go of this button before the run is complete this process is interrupted and must be started again If the initialisation run is interrupted the system cannot be move...