For devices between 900 and 1900 mm, the
controls are integrated in the device. The
connectors for the mains and ventilator are
located underneath the device. You require one
socket for the power supply.
The customer service must be able to access the
controls. Please provide two inspection openings
in the rear walls of kitchen furniture. Covers for
the inspection openings are included in the scope
of supply.
Electrical connection for recirculation mode
The controls are located on the rear or on the
left of the front side, next to the activated
carbon filters. The connectors for the mains and
ventilator are located on the ventilator control.
You require two sockets for the power supply.
Initial operation
Press the
button, the device must move
upwards. Once it is in the upper position, you can
switch on the ventilation. Check all the functions.
Press the
button, the device must move
downwards.
Should the hood not move, perform an
initialisation run (see page 6).
Move the hood several times and observe
whether the device runs in parallel.
After aligning the device and using for the first
time, secure it in a suitable place using the
mounting brackets supplied.
The brackets can be attached to the screws of
the device cladding or the screws in the side
parts. Attach the brackets as far down as
possible. The top of the device is fixed in place
in the work surface cut-out and can thus not
move. Should there be too much play here,
secure here as well to ensure that the device
remains stable.
If the downdraft ventilation is aligned in the
cut-out in the kitchen work surface and if the
loose cover is exactly flush with the work
surface in the lower position, you can also
adhere the cover to the mounting plate. The
cover must only be adhered to the mounting
plate and not to the housing. Make sure you
can still access the adjustable feet to allow
readjustment at a later date.
Subsequent minor adjustments can also be
made using both lifting cylinders. For this,
the upper cover must be removed.
The height can be adjusted by undoing the
fastening nut M10 and turning the setscrew
with an Allen key.
The tilt can be set by turning the magnets
5