29
4.
Programming Upper Flow Percentage:
1. Press mode button three times. Digital
readout will display current upper flow
setting. This represents the percent of
hydraulic flow that will be sent to the feed
rolls (Feed speed.).
2. Oil Use indicator will flash. Increase or
decrease setting using program buttons
(Kohler 38 HP gas: 60%. Kohler 25 HP
diesel: 50%).
5.
Programming Lower RPM Limit (Floor):
1. Press mode button four times. Digital
readout will display current lower limit set-
ting. This represents the RPM at which
the Auto-feed will suspend the feed rolls
completely.
2. Machine indicator will flash. Increase or
decrease setting using program buttons
(Kohler 38 HP gas: 985 RPM. Kohler 25
HP diesel: 985 RPM).
Fig. 10 READOUT
NOTE
Do not set above 80%.
Table 1 - Auto Feed Logic Curve
Flow
80
%
60
40
20
0
Rotor RPM
Ceiling
Floor
Fig. 11 READOUT