background image

Installation, Service Instructions & Parts

Quality Designed for Proven Performance

Printed in USA

8471 11

AVOID ERROR IN PARTS SELECTION.  When ordering use 

complete EMBERGLO Part Number and Description.  Furnish 

Model Number, Bill of Material Number and Serial Number (if 

available) from the specifi cation plate found on the product.

IMPORTANT:  Availability of parts as well as specifi cations are 

subject to change without notice.  Please consult factory for 

item availability.

SAFETY INFORMATION TERMS:

 The following terms are used to identify hazards, safety precaution of 

special notations and have standard meanings throughout this manual.  They are printed in all capital letters 
using a bold type face as shown below, and preceded by the exclamation mark symbol.  When you see the 
safety alert symbol and one of the safety information terms as shown below, be aware of the hazard potential.

DANGER:

 

Identifi es the most serious hazards which will result in severe personal injury or  
death.

WARNING:

  Signifi es a hazard that could result in personal injury or death.

CAUTION: 

Identifi es unsafe practices which would result in minor personal injury or product and      
property damage.

CAUTION: 

 

This steamer to be used with 

distilled water only (demineralized).

 Without treated 

water, deposits can build up in steam generators causing 
reduced steam volume and eventual stoppage of steam  
production. Clogged or limed steam generators caused 
by use of non-distilled water will not be covered under the 
terms of the warranty.

AR Series -Self Contained Water Reservoir and Pump - Stain-
less steel construction, Top injecting, portable, removable water 
drawer, manual pump or timer, 6′ - 3 wire cord.

Special Note: The AR Series requires distilled or demineral-
ized water. Clogged or limed  generators caused by use of 
non-treated water will not be covered under the terms of the 
warranty.

Specifi cations:

120 volts 60HZ AC 1500 watts, max 13 amp

240 volts 60HZ AC 1500 watts, max 6.3 amp
(240V model is Export Only and not UL listed)

Manual water pump operation

Closed generator

Drawer style steamer

C

O

M PAN

Y

R

E

G

IS TER

E

D

EmberGlo

A Div of Midco® International Inc.

 

4140 West Victoria Street
Chicago, Illinois 60646
toll free  866.705.0514
tel 

 773.604.8700

fax 

 773.604.4070

web 

 www.emberglo.com

e-mail   sales@emberglo.com

Warranty Form must be fi lled in and returned to EmberGlo to 
validate warranty. See warranty page for return instructions.

This manual contains suffi  cient information for installation of the 
EmberGlo Steamer in normal locations. 

 

In the United States, installation must conform with local codes. 

PURCHASER:  Retain these instructions for future use.

  

Post in a prominent location near the steamer.

CAUTION

: Cooking  equipment  should  be  used in 

an environment protected by an automatic fi re suppression    
system.  Consult the National Fire Protection Association NFPA 
Code 96 or the latest edition of Standards for Installation of 
Equipment for Removal of Smoke and Grease-Laden Vapors 
From Commercial Cooking Equipment.

 

WARNING:  Improper installation, adjustment, 

alteration, service or maintenance can cause property 
damage, injury or death.  Read the installation, operating 
and maintenance instructions thoroughly before install-
ing or servicing this equipment.

Warranty

See the back of this manual for warranty.

This warranty does not apply to damages resulting from         
accident, misuse, abuse or alteration.

No equipment may be returned without written authorization 
from EmberGlo (or Midco) . Returned goods must be shipped 
prepaid to the factory.

UL

®

718

AR60

Front Open
Self Contained Water Supply
Counter Top Steamer
Two Th

  irds Size Pan

120V and 240V Models

(240V Model for Export ONLY)

AR60 

Manual Operation with Water Pan 

120V 

5400400

AR60 

Manual Operation with Water Pan 

240V 

5400406

Models

Description

Volts 

BOMs

Summary of Contents for AR60

Page 1: ...ed water will not be covered under the terms of the warranty Speci cations 120 volts 60HZ AC 1500 watts max 13 amp 240 volts 60HZ AC 1500 watts max 6 3 amp 240V model is Export Only and not UL listed...

Page 2: ...necessary is determined by the type and amount of food to be heated For more than one shot wait 15 seconds between shots A shot is one operation of the lever __________________________________________...

Page 3: ...rator insulation This will expose a square plate on the generator which is removable for cleaning water passages Check the three exposed holes when the clean out cover is removed If any of these holes...

Page 4: ...eam chamber and then tighten the nuts with lock washers Remove all the tape __________________________________________ 1 Unit will not heat up light out a No power b Plug out c Loose internal connecti...

Page 5: ...min Poached 3 min Scrambled dz 5 min Meat Bratwurst 8 min 16 min Breakfast sausage 8 min 14 min Chicken breast lg 15 min 25 to 30 min Chicken breast precooked 5 min 15 min Deli meats 2 to 3 min Hambu...

Page 6: ...6 EmberGlo A Division of Midco International Inc 8471 11 DETAIL A DETAIL B A B 1 3 4 2 5 29 28 24 25 26 27 23 22 21 6 20 19 8 18 17 16 15 9 10 13 12 11 14 7 AR60 Exploded View...

Page 7: ...ment Kit Includes Bracket Dip Tube And Riser Tube Assemblies 1 26 5659 65 Crank Replacement Kit 1 27 2625 30 Food Steamer Pump Spring 1 28 1412 41 Thermostat Thermal Fuse Kit 1 29 5693 01 AR60 Riser T...

Page 8: ...briquettes or rods used in gas broilers Midco s obligation will be the replacement of the product or parts removed Terms Under the terms of this Limited Warranty Policy models considered portable dev...

Page 9: ...ctory for information 773 604 8700 Fill out form and fax to 773 604 4070 or copy and mail to EmberGlo A Division of Midco International 4140 West Victoria Street Date of Purchase End User Name Company...

Page 10: ...140 West Victoria Street Chicago Illinois 60646 PLACE STAMP HERE EmberGlo A Division of Midco International 4140 West Victoria Street Chicago Illinois 60646 toll free 866 705 0515 tel 773 604 8700 fax...

Reviews: