2
EmberGlo
A Division of Midco International Inc
8471 11
Maintenance
Daily as Required
Operation
Installation
1. Position steamer on level surface and plug power cord into 3-hole 120 volt AC grounded
receptacle. If an adapter is used, it must be grounded properly.
2. Pull out water pan and fi ll with distilled (NOT HOT OR BOILING) water to 1/4″ from the top of
the water pan baffl es; then close drawer. Unit is now ready for operation.
3.
No Hood Installation Required:
According to the Uniform Mechanical Codes per the
International Conference of Building Offi cials Code EmberGlo Steamers do not require a
separate hood for vapor produced during operation. Also, there are no requirements in NSF
Standard 4 (2006e) for steamers to have ventilation.
__________________________________________
1. Move toggle switch to ON position. The pilot indicating light remains on at all times.
Allow 15-20 minutes to reach operating temperature.
2. Open food drawer, place food in pan; close drawer and operate lever as required per cooking
guide.
3. At end of time cycle, open drawer and remove food.
4. Keep drawer closed when not in use.
5. To shut off unit move toggle switch to OFF position.
Caution: Operate lever to the left and return to vertical position. Rapid repeated op-
eration will over steam the unit. The amount of steaming necessary is determined by the type
and amount of food to be heated. For more than one shot, wait 15 seconds between shots. A
“shot” is one operation of the lever.
__________________________________________
The food pan is removed by lifting up. Clean the inside thoroughly and wipe the outside to remove
any material which might have accumulated.
-
To remove the food drawer, pull the drawer out until it stops, release stop located at rear
underside of drawer to unlock, and pull out the frame. Wipe the drawer and frame clean and
return by inserting the drawer slide into the slide of the frame, then push the food pan to the
rear until the lock engages automatically.
__________________________________________
DANGER: READ AND UNDERSTAND THIS BULLETIN THOROUGHLY BEFORE
STARTING ANY TROUBLE SHOOTING. AN INADVERTENT SERVICE ERROR COULD RESULT
IN SEVERE PERSONAL INJURY OR DEATH. ONLY A TRAINED EXPERIENCED SERVICE
TECHNICIAN SHOULD ATTEMPT ANY REPAIR PROCEDURE.
Qualifi ed serviced agencies are available at most locations - Refer to EmberGlo listing of
AUTHORIZED SERVICE AGENCIES included in Standard Equipment Catalog.
AR60 - Installation and Service
Service
Figure 1. Wiring for AR60 Steamer
Service to be performed by qualified personnel only
L2
L1
Blk
G
Gnd
Blk
Wht
LEGEND
Symbol
Description
Toggle Switch
Pilot Light
Thermostat
Generator
Over Heat
Protection Fuse
5646 10
Terminal Strip
E
Plug for 240 VAC to be Supplied by Installer
Material: (Outdoor/ Indoor Polyperm)
AR60 Wiring for
120/240 VAC Steamer