E2436 - Installation and Maintenance

Daily Maintenance

Preventative 
Maintenance

Installation

Wiring

:  All units are shipped wired for single phase current.  

Ventilation

:  Do not install broiler closer than 5″ to the back or 8″ on the side walls.  

LEGS SHIPPED 

WITH  THE  UNIT  MUST  BE  INSTALLED  WITH  LEG  CHANNELS. 

  Minimum  leg  height,  with  no 

blockage around the bottom of the broiler, must be maintained for proper ventilation. 

FAILURE  TO  INSTALL  OR  REMOVAL  OF  THE  LEGS  IS  A    VIOLATION  OF  THE  APPROVAL 
SEALS AND VOIDS THE MANUFACTURER’S WARRANTY.

  -  Remove  the  leg  channels  and  knobs  that  are  packed  in  the 
broiler (located in the hopper front).  The leg channels are two 
long  pieces  of  U-shaped  steel  designed  to  prevent  warping  of 
the broiler frame when the broiler is moved by sliding on its legs. 
See Figure 1
  -  Prop  the  broiler  up  and  line  up  the  holes  in  one  of  the  leg 
channels over the holes for the weld nuts on the front end of the 
broiler.
 - Screw two of the legs provided into the weld nuts to attach the 
legs and hold the leg channel in place.
 - Repeat procedure for the rear legs.

 

 

   

 

 

 

 

 

 

Figure 1 - Leg Placement

Turn the dial to “HI” and preheat for 20 minutes. Dial down to achieve desired cooking temperature. 

  

                          ______________________________________________

NOTE:  Always clean the unit starting at the top and working down.  Be sure that the grease hopper 
and grease pan are in place before you proceed with any cleaning procedure in order to prevent any 
scrapping or grease from dropping into the base and onto electrical wiring and terminal blocks.

 
 - With normal use of the broiler, deposits build up on the top and bottom of the grate.  In order to 
assure safe operation, these deposits must be cleaned periodically during the day from both the top 
and underside of the grill or grate casting.
 

a.  To clear the top of the casting, scrape each groove with the tip of the scraper provided  

 

 

 

until the surfaces are clear.

 

b.  To clear the underside of the casting, insert the scraper head through the slots of the  

 

 

 

grill and turn the scraper handle parallel to the grooves. Pulling upward, scrape    

 

 

 

deposits from the grill underside.  Repeat for each groove.

 

c.  Empty grease pan periodically to avoid messy overfl ow. 

 

 

   

 

 

                             ______________________________________________

 - When broiling is fi nished for the day clean as follows:
 

a.  Clean deposits from the top and bottom of the grate as explained above.

 

b.  Empty the hopper, clean and reinsert hopper.

 

c.  Turn unit to “HI” and leave on for approximately 20 minutes.  This will char the       

 

 

 

remaining grease on the grill casting.

 

d.  Turn off controls.  When grill is cool, scrape the underside again and wire brush the  

 

 

 

surface to complete cleaning of the grill.

 

e.  Remove and clean the side splash guards and rear trough.  Wash the front and rear  

 

 

 

wells and wipe along the sides.

 

f.  Wipe the casting with a dry clean cloth -- do not use water or detergent on the castings.

 

g.  Empty and clean the grease pan.

                             ______________________________________________

FRONT OF BROILER

LEG CHANNEL

LEG

Summary of Contents for E2436

Page 1: ...or use gasoline or other ammable liquids and vapors in the vicinity of this or any other appliance PURCHASER Retain these instructions for future use INSTALLER Inform and demonstrate to the user the c...

Page 2: ...e in place before you proceed with any cleaning procedure in order to prevent any scrapping or grease from dropping into the base and onto electrical wiring and terminal blocks With normal use of the...

Page 3: ...Division of Midco International Inc 8471 65 3 Schematics Figure 2A E2436 Schematics for 208 V and 240 V for Single Phase and 3 Phase E2436 Electrical Wiring Schematic 208 240 Volt 1600 33 208 V and 16...

Page 4: ...lo A Division of Midco International Inc 8471 65 Schematics Continued Figure 2A E2436 Schematics for 440 V and 480 V for 3 Phase E2436 Electrical Wiring Schematic 440 480 Volt 1600 35 440 V and 1600 3...

Page 5: ...Grease Pan 2 10 1605 00 Grease Pan Front 2 11 1900 03 E36 Control Panel 1 12 1615 00 Red Indicator Light Assembly 3 13 8445 15 In nite Knob 3 14 8425 20 In nite Switch 3 15 8408 52 3 Wire Terminal Str...

Page 6: ...he surface to complete cleaning of the grill 4 Always clean the unit starting at the top and working down Be sure that the grease hopper and grease pan are in place before you proceed with any cleanin...

Page 7: ...or does it apply to any consequential damages Most geographical areas require the use of distilled or demineralized water Tap water is permissible only with ES Series Steamers Nor does it apply to Bar...

Page 8: ...Division of Midco International 4140 West Victoria Street Chicago Illinois 60646 toll free 866 705 0515 tel 773 604 8700 fax 773 604 4070 web www emberglo com e mail sales emberglo com Printed in USA...

Reviews: