EmberGlo
A Division of Midco International Inc
MADE
in the
USA
2
ES10 Steamer Installation and Service
ES10 Steamers feature a 4″ deep full size steam table pan. The steamer lid is equipped with two
counter-balanced spring hinges and off ers a convenient choice of four locations for installing the
lid handle at the side or front of either front corner. Models Available for either manual or fully
automatic steaming.
Dimensions
Inches Centimeters
HEIGHT
(lid closed)
9 3/4″
24.77
HEIGHT
(lid open 90 degrees) with lid handle mounted on
front corner of lid, projecting forward.
29″
73.66
HEIGHT
(lid open 90 degrees) with lid handle mounted on
side corner of lid, projecting to the side.
23″
58.42
WIDTH
22 1/2″
57.15
WIDTH
with lid handle projecting to left or right side
28 1/2″
72.39
DEPTH
22″
55.88
____________________________________
Standard ES10 Steamers are designed for use with 208 VAC to 240 VAC, 4 (3 pole with ground)
wire, single phase, 60 Hz, electrical service. (See
Figure 2
). The generator casting contains two
heating elements, each rated for 1600 Watts. 13.3 amps, 120 Volts, 60 Hz. Models are available for
use on 50 Hz. (Non USA, Export only) electrical service. Call your distributor for more information.
Standard units are furnished with a six foot, four conductor (2 Hot/1 Neutral/1 Ground) cord. This
cord is equipped with a male twist-lock plug and matching loose female receptacle for convenient
fi eld installation.
____________________________________
Electrical
. Female twist-lock receptacle, supplied loose with the steamer, should be installed by a
qualifi ed electrician. Refer to wiring diagrams.
Figure 2
.
NOTE
: Female receptacle must be wired to assure that voltage to the individual heating elements
does not exceed 150 volts. (Circuits R-W and BK-W on Fig 1 and 2.) G terminal is wired to Ground
W terminal is wired to neutral. Protect circuit with a 15 amp double pole circuit breaker.
In the
United States
, Wiring to the Female receptacle must conform to local codes, or in the absence of
local codes, to the
National Electrical Code ANSI/NFPA No. 70-1990,
or latest edition. In Canada,
Wiring to the Female receptacle must conform to local codes, or in the absence of local codes,
to
Canadian Electrical Code Part 1, CSA Standard C22.1.
When choosing a location for the
steamer, be sure that there is adequate space over the unit to lift lid completely.
Water
. Connect water hose assembly to water supply system. The supply end has a 1/8″ female
pipe fi tting and should be attached downstream of a shut-off valve. Steamer end of hose has a quick
connect fi tting which snaps onto mating fi tting on steamer. This hose fi tting has an automatic shut-off
valve that allows steamer to be disconnected without shutting off water supply. After connecting, turn
on water and check for leaks.
No Hood Installation Required:
According to the Uniform Mechanical Codes per the International
Conference of Building Offi cials Code, EmberGlo Steamers do not require a separate hood for vapor
produced during operation.
Speci
fi
cations
Electrical
Installation