EmberGlo
A Division of Midco International Inc
8470 77
3
ES10 Steamer Installation and Service
Lid Angle Adjustment
: To adjust the angle of the lid to 60° or 90°
1. With the lid closed, loosen and remove slotted screw. Set aside.
2. Remove lid stop by sliding it up and away from the steamer.
3. Adjust lid stop for desired position (60° or 90° open) and place on steamer.
4. Insert and tighten slotted screw.
See at
Figure 1a, 1b and Figure 1c
for correct orientation.
Factory default setting is 60°
____________________________________
1. Push power switch to ON position (switch lights up). Allow approximately 15 minutes for
steamer to reach operating temperature.
2. MODEL ES10PB:
Push STEAM button momentarily for each shot of steam desired. Water is sprayed into the
steam generator for as long as the button is depressed. If the STEAM button is depressed too
long or too often, fl ooding of the steam generator will result. A one second shot of water every
20 seconds is a good rule of thumb to avoid fl ooding.
3. MODEL ES10:
A.) For a single-shot steaming as with the ES10PB (above), fl ip the CYCLE/MANUAL switch
to the MANUAL side. Push the STEAM button for each shot of steam desired.
B.) For unattended steaming for up to 20 minutes, set the CYCLE/MANUAL switch to CYCLE.
Depress the STEAM button to activate a steaming cycle. Steaming will proceed according to
the timer settings.
Timers are confi gured as follows:
CYCLE TIME:
Sets the total length of product cooking time, during which steam is
automatically supplied at adjustable intervals. At the end of the set time, steaming stops and
the buzzer sounds. Adjustable from 0.2 to 20 minutes.
STEAM SHOT “ON” TIME:
Sets the amount of time that water is supplied to the steam
generator to create steam. Adjustable from 0.1 to 0.5 seconds.
STEAM SHOT “OFF” TIME:
Sets the amount of the time between steam shots when no
steam is supplied. Adjustable from 6 to 18 seconds.
BUZZER DURATION:
Sets the length of time that the buzzer will sound after automatic
steaming is completed. Adjustable from 0.1 to 10 seconds.
DELAY FROM LAST SHOT TO BUZZER:
Sets the length of time between the last shot of
steam and the sounding of the buzzer. This dwell time allows absorption of steam into the
food. Adjustable from 0.1 to 30 seconds.
The adjustment features have been located within the steamer control box and made accessible
only with a screwdriver in order to discourage tampering or readjustments by unauthorized
personnel.
Operation
Figure 1a
Back of ES Series Steamer
60° Opening Position
Figure 1b
Back of ES Series Steamer
Lid Stop Reversed
90° Opening Position
1
2
1
2
Item # Part #
Description
1 HW1-099 #8-32 X 5/16″ Slotted
Pan Head Screw 18ss
2 1421-21
Lid Stop
90°
60°