ES10 Steamer Trouble Shooting Chart
DANGER: READ AND UNDERSTAND THIS BULLETIN THOROUGHLY BEFORE
STARTING ANY TROUBLE SHOOTING. AN INADVERTENT SERVICE ERROR COULD RESULT
IN SEVERE PERSONAL INJURY OR DEATH. ONLY A TRAINED EXPERIENCED SERVICE
TECHNICIAN SHOULD ATTEMPT ANY REPAIR PROCEDURE.
Quali
fi
ed service agencies are available at most locations—Refer to EmberGlo listing of
AUTHORIZED SERVICE AGENCIES included in Standard Equipment Catalog.
IMPORTANT: Defective wiring or loose connections can simulate the defects outlined below.
Check associated wiring before replacing a component.
1. UNIT DOES NOT HEAT—SWITCH ON, LIGHT OUT
A). Confi rm male twist-lock plug is plugged in and properly twisted (rotate clockwise).
B). Confi rm twist-lock receptacle is energized—reset breaker or repair house wiring.
WARNING: The following checks through 3. D. should be done with power cord
removed from receptacle.
C). Confi rm continuity in 4-conductor cord—replace if defective.
D). Confi rm continuity in double pole, single throw Power Switch, terminals 1-2 and 4-5 -
replace Power Switch if defective.
2. UNIT DOES NOT HEAT EVENLY OR STEAMS ONLY ON ONE END OF STEAM
GENERATOR CASTING—SWITCH ON, LIGHT ON.
A). Confi rm continuity of each of two Thermal Cut-off s— replace if defective.
B). Confi rm continuity of each of two Thermostats—replace if defective.
C). Confi rm continuity of each of two Heating Elements— replace entire Steam Generator
Casting if defective.
3. UNIT HEATS UP, BUT DOES NOT STEAM—NO WATER EVIDENT
A). Confi rm Manual Water Supply Valve is open and Water Hose Assembly is properly hooked
up. Refer to INSTALLATION-Water. A quick way to confi rm water line is operational is to
disconnect Water Hose at quick disconnect fi tting and push a small probe into quick disconnect
fi tting—water should fl ow freely.
B). Check and clean
Water Nozzles, Water Inlet
and
Strainers
.
Refer to
MAINTENANCE AS REQUIRED
.
C). Confi rm continuity of Steam Push Button Switch when depressed—replace if defective.
D). Confi rm continuity of water Solenoid Valve—replace if defective.
E). Water Solenoid Valve—Power Switch on, light on, confi rm 120 volts to GND on terminals
2 and 5 of Power Switch, both terminals of both Thermal Cut-off s, and terminal 3 of Square
Steam Button. With square Stem Button depressed, confi rm 120 volts to GND on terminal 4 of
Switch and blue lead terminal of Water Solenoid Valve. An audible click should be heard when
Valve is energized—if no click, jumper white lead terminal of Valve to GND. If click is heard with
jumper attached, white neutral wires are faulty from Valve thru both heater elements to neutral
on 4-conductor cord. Locate fault and repair. If no click, Water Solenoid Valve is defective and
should be replaced.
4. UNIT FLOODS—SELECTOR SWITCH TO MANUAL; SQUARE STEAM PUSH BUTTON NOT
DEPRESSED.
A. Water Solenoid Valve seat is dirty and valve cannot close completely or is defective clean or
replace as required.
WARNING: The following checks through Section 5 part B should be done with
power cord plugged in and properly twisted. Use extreme care as bare wire terminals
and/or bare wires are exposed.
5. UNIT FLOODS—SELECTOR SWITCH TO CYCLE
A. Same as 4.A.
B. STEAM SHOT, OFF TIME set for too frequent shots—refer to OPERATION 3B.