11
◼
Vibration
Operation (X-Y-Z): Sine vibration
Sine wave vibration test : Acceleration: 2g rms
✓
Frequency: 5 – 500 Hz
✓
Test Axis: X,Y,Z axis
✓
Test Time: 1 Hour per axis
✓
Total Test Time: 3 Hour
Operation (X-Y-Z): Random vibration
Random vibration test(Operating) : Accelerate: 2g rms
✓
Frequency: 5 – 500 Hz
✓
Test Axis: X,Y,Z axis
✓
Test Time: 1 Hour (Each axis).
✓
Total Test Time: 3 Hours
◼
Shock
50g peak acceleration (11 msec. duration)
◼
Certificate
CE / FCC class B / LVD
◼
Environmental
✓
Compliant with European Union RoHS (Restriction on
Use of Hazardous Substance in Electronic Equipment)
directive 2015/863/EU
✓
RoHS restricts the use of Lead (Pb) < 0.1% or
1,000ppm, Mercury (Hg) < 0.1% or 1,000ppm,
Cadmium (Cd) < 0.01% or 100ppm, Hexavalent
Chromium (Cr6+) < 0.1% or 1,000ppm,
Polybrominated biphenyls (PBBs) < 0.1% or
1,000ppm, Polybrominated diphenyl Ethers (PBDEs) <
0.1% or 1,000ppm,
Bis (2-ethylhexyl) phthalate
(DEHP)<0.1% or 1,000ppm , Butyl benzyl phthalate
(BBP)<0.1% or 1,000ppm , Dibutyl phthalate (DBP)<0.1%
or 1,000ppm , and Diisobutyl phthalate (DIBP)<0.1% or
1,000ppm