USB port (option) 

Connecting the UPS to your computer is accomplished through the USB port on the back 
of your computer. USB compliant hardware and operating system will be necessary 
including installation of a UPS driver. The serial port cannot be used when using the USB 
port. The USB cable is standard and can be bought separately. 

6.1 EPO port (emergency power off) 

A customer-supplied switch located remotely can be used to open the EPO connection 
and allows UPS output receptacles to be switched off. Since the EPO shuts down the 
equipment immediately, orderly shutdown procedures are not followed and not by any 
power management software. The UPS will have to be manually restarted in order to 
regain power to the outlets. 

 

7.  User’s guide to operations 

Necessary information for operation of the unit is covered in this chapter. 
Normally the UPS runs automatically, but on those few occasions such as 
just after installation, all the starting and shutting down procedures are 
described herein. 

7.1 Starting and shutting down the UPS 

Starting the UPS 

z

 

Ensure that installation was correct and successful and that the input power cable is 
connected to a well-grounded outlet. 

z

 

The UPS can be started by pushing the “ON/OFF” button on the front panel. 

z

 

The UPS should now start its inspection of: internal functions, main synchronization 
and inverter startup. Then power should start to be supplied via the terminal block. 

z

 

During this inspection, the LCD will display “Ready on”. The LED shall light up 
when output power has commenced and the LCD will display “Line mode”. 

z

 

Switch on the loads. 

Shutting down the UPS 

z

 

Shut down and turn off the loads. 

z

 

Push the “ON/OFF” button on the front panel for two seconds. The alarm will sound 
and the UPS will shut down. 

z

 

The LCD will display UPS OFF for a few seconds. 

z

 

In emergency situations, the EPO located on the back of the unit should be used. 

 

19

7.2 Button operation 

Please note the five operating buttons on the front panel: 

1.

 

“ON/OFF” button: 

(a)

 

Push “ON/OFF” button (at least 1 seconds) to turn on the UPS. 

(b)

 

When UPS is working, push the “ON/OFF” button(at least 2 seconds) to turn 

off the UPS. 

2.

 

“STATUS” button:   

Use this button to check content of UPS and the method is listed

 

below: 

(a)

 

Push the “STATUS” button (at least 2 seconds) to check content of UPS. 

Each content can be displayed by pressing at once, and it has fifteen kinds of 

function to be checked. 

(b)

 

If no pressing within 10 seconds, it will return to original status. 

3.

 

“FUNC” button: 

Each function can be enabled by pressing this button & “ENTER” button. 

(a)

 

Push the “FUNC ” button (at least 2 seconds) to choose which function that 

you want. Each content can be displayed by pressing at once, and it has 

fourteen kinds of function to be checked. 

(b)

 

After choosing the function, push the “ENTER” button to enter the function 

that you want. 

(c)

 

Push the “FUNC” button to choose other function again. 

(d)

 

Push the “ENTER” button to enable your function. 

(e)

 

Push the “ENTER” button to confirm and enable your function. 

(f)

 

If no pressing within 10 seconds, it will return to original status. 

4.

 

“ENTER” button: 

Use this button to enter

enable or confirm the function that you want. 

5.

 

“ESCAPE” button: 

Use this button to return to main display(Line mode or Battery Mode). 

Summary of Contents for 4K VA 20K VA UPS

Page 1: ...ced by harmful interference from the equipment it is recommended to use one of the following preventive measures z Place the receiving antenna in a separate location or orientation z Ensure a greater...

Page 2: ...ide Refer servicing to qualified service personnel CAUTION Non isolated Battery supply Risk of electric shock battery circuit is not isolated from AC input hazardous voltage may exist between battery...

Page 3: ...lation must be carried out in accordance with this manual Electrical installations must also carefully follow local legislation and regulations Only qualified personnel should conduct these installati...

Page 4: ...ions of the batteries sends any forewarnings if replacement is needed Otherwise every 30 days of normal mode operation a battery discharge test is performed and any problems reported on the LCD displa...

Page 5: ...e very hazardous to the operator 5 4 Storage Please adhere to the following instructions if the UPS is not installed immediately z Store the equipment as is in its original packing and shipping carton...

Page 6: ...6 5 2 Rear panel views 4K 5KVA 120VDC Rear panel 7 6KVA Rear panel Without ISO...

Page 7: ...8 6KVA Rear panel With ISO 9 8K 10KVA Rear panel Without ISO...

Page 8: ...10 8K 10 KVA Rear panel With ISO 11 12KVA Rear panel ISO and With ISO...

Page 9: ...nstalled z Be aware of UPS parameters and changing the Battery pack quantity when using the external battery cabinets see chapter 7 2 Installing UPS z Ensure that the installation site has all electri...

Page 10: ...connections be used use connections according to chapter 6 of the manual provided with that option The connections can be referred to on the rear panel z The installation is now complete b removable j...

Page 11: ...munications cards It can be used parallel with either the RS232 or USB ports Currently there are two cards available for the optional interface slot An SNMP WEB card allows management and monitoring o...

Page 12: ...tput power has commenced and the LCD will display Line mode z Switch on the loads Shutting down the UPS z Shut down and turn off the loads z Push the ON OFF button on the front panel for two seconds T...

Page 13: ...rol panel Normal display The UPS status is shown in normal display mode From here you have a choice to go to UPS meters display and the Setting display by pushing the button UPS meters display Various...

Page 14: ...t Input Voltage range when bypass is available 10 10 15 15 20 10 15 Free Run Mode Free Run Set Select if UPS can run in Free run mode unsynchronized ON OFF ON Bypass Enable Disable at Free run mode By...

Page 15: ...tness any alarm indication on the control panel Alarm indicators The UPS gives the following audible alarms z If UPS is on battery and the ON BATTERY LED is on UPS will beep every 5 seconds z If the b...

Page 16: ...Low Output Voltage Constant beep Low output voltage Call the Local dealer Bus Fault 2 Beeps per second High internal DC bus Voltage Turn off protected loads Turn off UPS and call your local dealer Si...

Page 17: ...h W ISOTR 342 x 690 x 715 13 4 x 27 2 x 28 1 342 x 690 x 878 13 5 x27 2 x34 6 342 x 863 x 905 13 5 x 34 0 x 35 6 Physical Net Weight kg lb W ISOTR 130 0 286 0 176 5 388 3 225 0 495 0 29 Shipping Weigh...

Page 18: ...lf test adjustable battery transfer points and alarm settings Battery Battery Protection Cut off without draining any current when battery is low 31 Cold Start DC start YES Back Up Time Tower model Ab...

Page 19: ...Receptacles Hardwire Dimensions W x D x H mm inch TBD 428 597 260 18 9 23 5 10 2 428 658 260 18 9 25 9 10 2 Net Weight kg lb TBD 86Kg 189lb 110Kg 242lb Physical Shipping Weight kg lb TBD 100Kg 220lb 1...

Page 20: ...MPONENT INCLUDING 3U UPS 3U BATT CABINET FRONT VIEW REAR VIEW 35 2 UPS REAR PANEL COMPONENTS H TERMINAL BLOCK I BREAKER J EXTERNAL BATTERY CONNECTOR K BYPASS SWITCH L SNMP SLOT M RS232 EPO N TVSS O US...

Page 21: ...TION a Remove the original right side panel and take apart the control panel unit Then assemble the blank right side panel b Connect the Control panel unit and Remote control port from rear side 37 c...

Page 22: ...ge the position of the two mounting brackets to mount the 3U rack mount in a 23 inch EIA 310 C standard rack 3 Tower installation a Move the mounting brackets from the front to the side and attach the...

Page 23: ...ting brackets from the front to the side and attach the brackets by screws Then mount the UPS to the wall as the below pictures shown 5 Installation with rear Bracket We can use bracket to support the...

Reviews: