2-20
Setting Up and Starting a CX700 System
3. To connect to a 2-Gbit switch or host bus adapter (HBA) port,
refer to Figure 2-14; for a 1-Gbit switch or HBA port, refer to
Figure 2-15.
a. Connect the external end of the Port 0-2 cables as follows:
– For a
direct attach
configuration— to the host server’s host
bus adapter (HBA).
If the HBA is not yet installed in the host server, refer to the
Installation
Roadmap for CX-Series, AX-Series, and FC-Series Storage Systems
for
instructions on configuring hosts, then connect the SP.
– For a
storage area network (SAN)
configuration — to a Fibre
Channel switch port.
b. Connect the external end of the Port 3 (outside) cable as
follows:
– In a system
without MirrorView™ software
— to an HBA
port (direct-attach configurations) or switch port (SAN
configurations).
– In a system
with MirrorView
— to a corresponding storage
processor (SP) host port on the remote storage system.
Figure 2-14
Connecting to a 2-Gbit Switch or HBA
EMC2286
To 2-Gbit HBA
or switch port