1-4
EMC CX200-Series DPE2 Hardware Reference
About the CX200-Series DPE2
A CX200 system can continue running in a degraded mode with one
operating power supply and one functioning SP. You should replace a
failed FRU as soon as possible.
Figures 1-2 through 1-4 show the enclosure components. Where the
enclosure provides slots for two identical components, the
components are called component-name A or component-name B, as
shown in the illustrations.
For increased clarity, the following figures 1-2 through 1-10 depict the DPE2
outside of the rack cabinet. Your enclosure may be installed in a rackmount
cabinet as shown in Figure 1-1.
As shown in Figure 1-2, the front LED display contains two status
lights for each disk module, and two disk enclosure status lights. The
status lights are visible with the front bezel installed.
Figure 1-2
CX200 DPE2 Front LED Display
Figure 1-3 shows the DPE2 components visible from the rear of the
cabinet.
EMC2166
Power LED
(Green)
Fault LED
(Amber)
Fault LED
(Amber)
Disk Activity
LED
(Green)