EMC CX200-Series DPE2 Hardware Reference
Installing a CX200-Series DPE2
Making Back End
Connections
1. Attach copper cables from the CX200 DPE2 to additional disk
enclosures, as shown in Figure 2-6.
Figure 2-6
Connecting a CX200 DPE2 to Another Disk Enclosure
Connect the back end (BE) on the CX200 to the Primary (PRI)
connector in any additional disk enclosure (EA 1).
2. Disk-array enclosures cabled together should appear as shown in
The example configuration in Figure 2-7 shows a CX200 below a DAE2
disk-array enclosure. The two devices support a redundant loop 0. Note that
the CX200 connects to the Primary disk enclosure connectors.
Figure 2-7
Cabling a CX200 and Disk Enclosure Together
EMC2469
To DAE2
BE
Connector
EXP
EXP
PRI
PRI
EA1/Loop 0
EA0/Loop 0
Loop 0
Loop 0
LCC B
LCC A
BE
BE
EMC2470