3
3-52
EMC Disk-Array Processor Enclosure (DPE) Deskside Model FC4400/4500 Hardware Reference
Servicing and Upgrading a Deskside DPE
Figure 3-38
For Power Supplies Installed with the Power Switch at the Top
Latch
Power supply
Channel
Channel
A.
Make sure that the supply’s latch is as far down in its slot as possible.
B.
Align the supply with the enclosure slot and gently push the supply
into the slot until the latch moves to middle of the slot.
C.
With your thumb, push the latch up until it engages. You may need to brace
your hand against the supply’s handle.
IMPORTANT: The cord must not occupy the space for the drive fan pack.
D.
Insert the power cord’s right-angle plug into the supply’s ac receptacle.
E.
Bend the cord into a U shape and slide the U into the channel so the
end of the cable comes out of the channel at the back of the enclosure.