Technical Specifications
A-3
Specifications and Operational Requirements
For the DAE
Enclosure
Size and Weight
ac protection
12-A thermal circuit breaker in each DPE power supply
15-A thermal circuit breaker at each ac inlet (each PDU)
ac receptacle type
IEC320-C14 appliance coupler
Hold-up time
10 ms min at 50 Hz
Current sharing
60% max, 40% min (redundant power configuration only)
Requirement
Description
Requirement
Description
ac line voltage
100 to 240 Vac + 10%, single phase, 47 to 63 Hz
ac line current
4.0 A max estimate at 100 V (fully configured)
Power consumption
400 VA max estimate (fully configured)
Power dissipation
392 W max estimate (fully configured)
Power factor
0.98 min at full load, low voltage
Heat dissipation
1411 x 10
3
J/hr (1340 BTU/hr) max estimate
In-rush current
25 A max estimate for 1/2 line cycle, per power supply
ac protection
8-A magnetic circuit breaker on each power supply
15-A thermal circuit breaker on each PDU
ac receptacle type
IEC320-C14 appliance coupler
Hold-up time
10 ms min at 50 Hz
Current sharing
60% max, 40% min (redundant power configuration only)
Requirement
Description
Height
68.0 cm (26.8 in)
Width
52.1 cm (20.6 in)
Depth
74.7 cm (30.0 in) front door to
back of unit
Weight
Enclosure with max configuration (including
2 SPs) 143.6 kg (316 lbs)
SP - 1.8 kg (4.0 lbs)
SP fan pack - 1.8 kg (4.0 lbs)
LCC, DPE - 0.8 kg (1.7 lbs)
LCC, DAE - 0.68 kg (1.5 lbs)
SPS - 10.9 kg (24 lbs)
Disk module - 1.05 kg (2.3 lbs)
Power supply, DPE - 5.4 kg (12 lbs)
Power supply, DAE - 3.8 kg (8.5 lbs)
Drive fan pack - 1.8 kg (4.0 lbs)