3
Replacing or Adding an LCC Module
3-37
Servicing and Upgrading a Deskside DPE
Replacing or Adding an LCC Module
CAUTION
!
Handle an LCC gently and use an ESD wristband. Do not remove a
faulty LCC until you have a replacement module or filler module
available.
DPE and DAE enclosures with two LCCs should have at least one LCC
installed while the deskside DPE is powered up. Try not to remove both
LCCs within a DPE or DAE enclosure while the deskside DPE is powered up.
Removing an LCC
1. If you are adding a new LCC, remove the LCC filler module as
shown below; otherwise continue to the next step.
Figure 3-25
Removing an LCC Filler Module
Proceed to the LCC installation procedure to install the add-on
LCC in the slot you just emptied.
A.
Push the latch to the
left to release the
filler module.
B.
Grasp the filler module
and pull it out of the
enclosure.