CL4032
Figure 21
Install Blade Enclosure Bezel
2. [ ] Push the bezel in until you feel it snap into place. Pull back on the bezel lightly to ensure it is
secure.
3. [ ] Lock the bezel by turning the key clockwise.
Task 13: Check System Status
You should still be in your HyperTerminal or PuTTY session.
1. [ ] Enter the following command to verify the system state:
#
/nas/bin/nas_checkup
Example:
# /nas/bin/nas_checkup
Check Version:
<NAS_version>
Check Command: /nas/bin/nas_checkup
Check Log : /nas/log/checkup-run.100128-181007.log
-------------------------------------Checks-------------------------------------
Control Station: Checking if file system usage is under limit.............. Pass
Control Station: Checking if NAS Storage API is installed correctly........ Pass
Control Station: Checking if NBS clients are started....................... Pass
Control Station: Checking if NBS configuration exists...................... Pass
Control Station: Checking if NBS devices are accessible.................... Pass
Control Station: Checking if NBS service is started........................ Pass
Storage System : Checking for unsupported storage profile.................. Pass
Storage System : Checking if Fibre Channel zone checker is set up.......... N/A
Storage System : Checking if Fibre Channel zoning is OK.................... N/A
Storage System : Checking if proxy arp is setup............................ Pass
Storage System : Checking SPA SPB communication............................ Pass
--------------------------------------------------------------------------------
If the output of the
nas_checkup
command indicates any problems, correct the problems and re-do the
command before continuing.